Efficacy of Foreign Body Removal using a Cryoprobe in Flexible Bronchoscopy
Autor: | Tae Won Jang, Nam Kyu Kim, Mann Hong Jung, Chul Ho Oak, Go Eun Yeo, Eun Jeong Kim, So Young Ock, Yu Jin Han, Weon Hyoung Lee, Sung-Jin Nam |
---|---|
Rok vydání: | 2014 |
Předmět: | |
Zdroj: | Kosin Medical Journal. 29:31-36 |
ISSN: | 2586-7024 2005-9531 |
DOI: | 10.7180/kmj.2014.29.1.31 |
Popis: | ObjectivesEndobronchial foreign body impaction is a medical emergency because of the air way obstruction. Therefore, immediate foreign body removal is crucial in such situations. Recently, there have been several reports about cryoprobe use as a tool for removal of foreign bodies. In this study, we determined the efficacy and complications of foreign body removal using a cryoprobe during flexible bronchoscopy.MethodsThis is a retrospective review of 27 patients who visited Kosin University Gospel Hospital from August 2007 to August 2010 with respiratory symptoms due to a foreign body in the airway. There were 17 males and 10 females, aged from 7 to 78 years. The foreign bodies were more frequently located (55%) in the right bronchus. The cryoprobe was inserted through the forceps channel of the flexible bronchoscope under local anesthesia. The lesion was quickly frozen for 5 seconds at -80℃, and the bronchoscope was removed with the probe after crystal formation on the contacted area.ResultsThe success rate of removal of foreign bodies was 85% (23/27) using the cryoprobe. One case of broncholith did not undergo attempted removal because of the possibility of excessive hemorrhage by the tight bronchus impaction, and three cases (plastic, silicon, and implant) failed due to limited crystal formation. There were no severe hemorrhages, arrhythmias, or casualties during the procedure.ConclusionsThe removal of foreign body using a cryoprobe during flexible bronchoscopy was shown to be safe and effective. The nature of the material should be attempted before removing a foreign body. |
Databáze: | OpenAIRE |
Externí odkaz: |