Comparison between qualitative and quantitative assessment of background parenchymal enhancement on breast MRI
Autor: | Henry Rusinek, Amy N. Melsaether, Yiming Gao, Artem Mikheev, Jerzy Walczyk, Chloe Chhor, James S. Babb, Kristine Pysarenko, Harikrishna Rallapalli, Melanie Moccaldi, Akshat C. Pujara |
---|---|
Rok vydání: | 2017 |
Předmět: |
Gynecology
education.field_of_study medicine.medical_specialty Receiver operating characteristic medicine.diagnostic_test business.industry Concordance Population medicine.disease 030218 nuclear medicine & medical imaging 03 medical and health sciences 0302 clinical medicine Breast cancer Region of interest 030220 oncology & carcinogenesis medicine Breast MRI Radiology Nuclear Medicine and imaging Stage (cooking) education Nuclear medicine business Kappa |
Zdroj: | Journal of Magnetic Resonance Imaging. 47:1685-1691 |
ISSN: | 1053-1807 |
DOI: | 10.1002/jmri.25895 |
Popis: | Background Potential clinical implications of the level of background parenchymal enhancement (BPE) on breast MRI are increasing. Currently, BPE is typically evaluated subjectively. Tests of concordance between subjective BPE assessment and computer-assisted quantified BPE have not been reported. Purpose or hypothesis To compare subjective radiologist assessment of BPE with objective quantified parenchymal enhancement (QPE). Study type Cross-sectional observational study. Population Between 7/24/2015 and 11/27/2015, 104 sequential patients (ages 23 - 81 years, mean 49 years) without breast cancer underwent breast MRI and were included in this study. Field strength/sequence 3T; fat suppressed axial T2, axial T1, and axial fat suppressed T1 before and after intravenous contrast. Assessment Four breast imagers graded BPE at 90 and 180 s after contrast injection on a 4-point scale (a-d). Fibroglandular tissue masks were generated using a phantom-validated segmentation algorithm, and were co-registered to pre- and postcontrast fat suppressed images to define the region of interest. QPE was calculated. Statistical tests Receiver operating characteristic (ROC) analyses and kappa coefficients (k) were used to compare subjective BPE with QPE. Results ROC analyses indicated that subjective BPE at 90 s was best predicted by quantified QPE ≤20.2 = a, 20.3-25.2 = b, 25.3-50.0 = c, >50.0 = d, and at 180 s by quantified QPE ≤ 32.2 = a, 32.3-38.3 = b, 38.4-74.5 = c, >74.5 = d. Agreement between subjective BPE and QPE was slight to fair at 90 s (k = 0.20-0.36) and 180 s (k = 0.19-0.28). At higher levels of QPE, agreement between subjective BPE and QPE significantly decreased for all four radiologists at 90 s (P ≤ 0.004) and for three of four radiologists at 180 s (P ≤ 0.004). Data conclusion Radiologists were less consistent with QPE as QPE increased. Level of evidence 3 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2018;47:1685-1691. |
Databáze: | OpenAIRE |
Externí odkaz: |