Effect of a substrate on the temperature distribution in an argon-hydrogen thermal plasma jet

Autor: Armelle Vardelle, Michel Vardelle, R. J. Kearney, Pierre Fauchais, D. Lapierre
Rok vydání: 1994
Předmět:
Zdroj: Plasma Chemistry and Plasma Processing. 14:407-423
ISSN: 1572-8986
0272-4324
DOI: 10.1007/bf01570204
Popis: Gas temperature profiles in the plume of an argon-hydrogen thermal plasma jet were determined /torn Rayleigh scattered laser light. Measured profiles were found to be well fitted by a Gaussian curve. Temperature data were compared with values obtained from thermocouples and showed an increasing discrepancy for temperatures higher than 800 K. The presence Q1 a cooled substrate in the flow was observed to increase the center-line temperature by about 22 at the substrate. By, combining the temperature results with calorimetric measurements of heal fox, a heat transfer coefficient to a copper substrate held at 300 K Iras determined to be in the range 400–1000 W/m2. K under typical plasma spraying conditions.