ANALYZING THE USE OF GASEOUS HELIUM AS A PRESSURANT WITH CRYOGENIC PROPELLANTS WITH THERMODYNAMIC VENTING SYSTEM MODELLING AND TEST DATA

Autor: A. Hedayat, S. L. Nelson, L. J. Hastings, R. H. Flachbart, D. J. Vermilion, S. P. Tucker, J. G. Weisend, John Barclay, Susan Breon, Jonathan Demko, Michael DiPirro, J. Patrick Kelley, Peter Kittel, Arkadiy Klebaner, Al Zeller, Mark Zagarola, Steven Van Sciver, Andrew Rowe, John Pfotenhauer, Tom Peterson, Jennifer Lock
Rok vydání: 2008
Předmět:
Zdroj: AIP Conference Proceedings.
ISSN: 0094-243X
DOI: 10.1063/1.2908511
Popis: Cryogens are viable candidate propellants for NASA's Lunar and Mars exploration programs. To provide adequate mass flow to the system's engines and/or to prevent feed system cavitation, gaseous helium (GHe) is frequently considered as a pressurant. During low gravity operations, a Thermodynamic Venting System (TVS) is designed to maintain tank pressure during low gravity operations without propellant resettling. Therefore, a series of tests were conducted in the Multi-purpose Hydrogen Test Bed (MHTB) of Marshall Space Flight Center (MSFC) in order to evaluate the effects of GHe pressurant on pressure control performance of a TVS with liquid hydrogen (LH2) and nitrogen (LN2) as the test liquids. The TVS used in these test series consists of a recirculation pump, Joule-Thomson (J-T) expansion valve, and a parallel flow concentric tube heat exchanger combined with a longitudinal spray bar. Using a small amount of liquid extracted from the tank recirculation line, passing it through the J-T valve, and then through the heat exchanger, thermal energy is extracted from the bulk liquid and ullage thereby enabling pressure control. The LH2/GHe tests were performed at fill levels of 90%, 50%, and 25% and LN2/GHe tests were conducted at fill levels of 50% and 25%. Moreover, each test was conducted with a specified tank ullage pressure control band. A one-dimensional TVS performance program was used to analyze and correlate the test data. Predictions and comparisons with test data of ullage pressure and temperature and bulk liquid saturation pressure and temperature with test data are presented.
Databáze: OpenAIRE