Autor: |
Zachary A Medress, Karen Malacon, Harsh Wadhwa, Christopher Leung, Matthew Sklar, Corinna C. Zygourakis |
Rok vydání: |
2021 |
Předmět: |
|
Zdroj: |
Journal of Neurosurgery: Case Lessons. 1 |
ISSN: |
2694-1902 |
DOI: |
10.3171/case2125 |
Popis: |
BACKGROUND Vertebral artery injury is a devastating potential complication of C1–2 posterior fusion. Intraoperative navigation can reduce the risk of neurovascular complications and improve screw placement accuracy. However, the use of intraoperative computed tomography (CT) increases radiation exposure and operative time, and it is unable to image vascular structures. The Machine-vision Image Guided Surgery (MvIGS) system uses optical topographic imaging and machine vision software to rapidly register using preoperative imaging. The authors presented the first report of intraoperative navigation with MvIGS registered using a preoperative CT angiogram (CTA) during C1–2 posterior fusion. OBSERVATIONS MvIGS can register in seconds, minimizing operative time with no additional radiation exposure. Furthermore, surgeons can better adjust for abnormal vertebral artery anatomy and increase procedure safety. LESSONS CTA-guided navigation generated a three-dimensional reconstruction of cervical spine anatomy that assisted surgeons during the procedure. Although further study is needed, the use of intraoperative MvIGS may reduce the risk of vertebral artery injury during C1–2 posterior fusion. |