Development of a 4000-scanning-lines high-resolution TV camera for real-time digital radiography system
Autor: | Yukio Takasaki, Yokouchi Hisatake, Yoichi Onodera |
---|---|
Rok vydání: | 1993 |
Předmět: | |
Zdroj: | SPIE Proceedings. |
ISSN: | 0277-786X |
DOI: | 10.1117/12.154619 |
Popis: | We have developed a 4200 scanning lines TV camera using a 2-inch diameter, electrostatic focus and electrostatic deflection type SATICONTM image pick-up tube which have been newly developed for real-time digital radiography (DR) system. We obtained 23% in AR value at 2600 TV line and 47.4 dB in S/N value at signal current 1200 nA in 4000 lines mode.© (1993) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only. |