Investigating deformable image registration and scatter correction for CBCT-based dose calculation in adaptive IMPT

Autor: Kurz, Christopher, Kamp, Florian, Park, Yang-Kyun, Zöllner, Christoph, Rit, Simon, Hansen, David, Podesta, Mark, Sharp, Gregory C, Li, Minglun, Reiner, Michael, Hofmaier, Jan, Neppl, Sebastian, Thieke, Christian, Nijhuis, Reinoud, Ganswindt, Ute, Belka, Claus, Winey, Brian, Parodi, Katia, Landry, Guillaume
Přispěvatelé: Promovendi ODB, Radiotherapie, RS: GROW - School for Oncology and Reproduction, RS: FHML non-thematic output, RS: GROW - R3 - Innovative Cancer Diagnostics & Therapy, Department of Radiation Oncology [Munich], Ludwig-Maximilians-Universität München (LMU), Department of Medical Physics, Department of Radiation Oncology [Boston], Harvard Medical School [Boston] (HMS)-Massachusetts General Hospital [Boston], Imagerie Tomographique et Radiothérapie, Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé (CREATIS), Université Jean Monnet [Saint-Étienne] (UJM)-Hospices Civils de Lyon (HCL)-Institut National des Sciences Appliquées de Lyon (INSA Lyon), Université de Lyon-Institut National des Sciences Appliquées (INSA)-Université de Lyon-Institut National des Sciences Appliquées (INSA)-Université Claude Bernard Lyon 1 (UCBL), Université de Lyon-Centre National de la Recherche Scientifique (CNRS)-Institut National de la Santé et de la Recherche Médicale (INSERM)-Université Jean Monnet [Saint-Étienne] (UJM)-Hospices Civils de Lyon (HCL)-Institut National des Sciences Appliquées de Lyon (INSA Lyon), Université de Lyon-Centre National de la Recherche Scientifique (CNRS)-Institut National de la Santé et de la Recherche Médicale (INSERM), Department of Oncology, Aarhus University Hospital, Maastricht Radiation Oncology Clinic (MAASTRO), Maastricht University [Maastricht], Université Claude Bernard Lyon 1 (UCBL), Université de Lyon-Université de Lyon-Institut National des Sciences Appliquées de Lyon (INSA Lyon), Université de Lyon-Institut National des Sciences Appliquées (INSA)-Institut National des Sciences Appliquées (INSA)-Hospices Civils de Lyon (HCL)-Université Jean Monnet [Saint-Étienne] (UJM)-Institut National de la Santé et de la Recherche Médicale (INSERM)-Centre National de la Recherche Scientifique (CNRS)-Université Claude Bernard Lyon 1 (UCBL), Université de Lyon-Institut National des Sciences Appliquées (INSA)-Institut National des Sciences Appliquées (INSA)-Hospices Civils de Lyon (HCL)-Université Jean Monnet [Saint-Étienne] (UJM)-Institut National de la Santé et de la Recherche Médicale (INSERM)-Centre National de la Recherche Scientifique (CNRS)
Jazyk: angličtina
Rok vydání: 2016
Předmět:
Zdroj: Medical Physics, 43(10), 5635-5646. Wiley
Medical Physics
Medical Physics, American Association of Physicists in Medicine, 2016, 43 (10), pp.5635-5646. ⟨10.1118/1.4962933⟩
ISSN: 0094-2405
DOI: 10.1118/1.4962933⟩
Popis: International audience; Purpose:This work aims at investigating intensity corrected cone-beam x-ray computed tomography (CBCT) images for accurate dose calculation in adaptive intensity modulated proton therapy (IMPT) for prostate and head and neck (H&N) cancer. A deformable image registration (DIR)-based method and a scatter correction approach using the image data obtained from DIR as prior are characterized and compared on the basis of the same clinical patient cohort for the first time.Methods:Planning CT (pCT) and daily CBCT data (reconstructed images and measured projections) of four H&N and four prostate cancer patients have been considered in this study. A previously validated Morphons algorithm was used for DIR of the planning CT to the current CBCT image, yielding a so-called virtual CT (vCT). For the first time, this approach was translated from H&N to prostate cancer cases in the scope of proton therapy. The warped pCT images were also used as prior for scatter correction of the CBCT projections for both tumor sites. Single field uniform dose and IMPT (only for H&N cases) treatment plans have been generated with a research version of a commercial planning system. Dose calculations on vCT and scatter corrected CBCT (CBCT cor) were compared by means of the proton range and a gamma-index analysis. For the H&N cases, an additional diagnostic replanning CT (rpCT) acquired within three days of the CBCT served as additional reference. For the prostate patients, a comprehensive contour comparison of CBCT and vCT, using a trained physician’s delineation, was performed.Results:A high agreement of vCT and CBCT cor was found in terms of the proton range and gamma-index analysis. For all patients and indications between 95% and 100% of the proton dose profiles in beam’s eye view showed a range agreement of better than 3 mm. The pass rate in a (2%,2 mm) gamma-comparison was between 96% and 100%. For H&N patients, an equivalent agreement of vCT and CBCT cor to the reference rpCT was observed. However, for the prostate cases, an insufficient accuracy of the vCT contours retrieved from DIR was found, while the CBCT cor contours showed very high agreement to the contours delineated on the raw CBCT.Conclusions:For H&N patients, no considerable differences of vCT and CBCT cor were found. For prostate cases, despite the high dosimetric agreement, the DIR yields incorrect contours, probably due to the more pronounced anatomical changes in the abdomen and the reduced soft-tissue contrast in the CBCT. Using the vCT as prior, these inaccuracies can be overcome and images suitable for accurate delineation and dose calculation in CBCT-based adaptive IMPT can be retrieved from scatter correction of the CBCT projections.
Databáze: OpenAIRE