Radon Properties in Offices.

Autor: Yu, K. N., Young, E. C. M., Stokes, A. J., Tang, K. K.
Zdroj: Health Physics; Aug1998, Vol. 75 Issue 2, p159-164, 6p
Abstrakt: The radon concentration (RC), total potential alpha energy concentration of radon decay products (PAEC), equilibrium factor (F), and the fraction of unattached radon decay products (fp) were measured for 94 offices in Hong Kong. The mean values for RC, PAEC, F, and fp were 51 Bq m-3, 1.19 × 10-7 J m-3 (5.7 mWL), 0.43, and 0.13, respectively. The first three are much higher than the corresponding values for dwellings. The radon properties vary significantly for different sites. The time for measurements, cumulative time since the air conditioning system was turned on, and whether smoking is allowed in the office have been identified from the available data as possible factors affecting the radon characteristics in offices. The mean contribution of the lung exposure to the annual effective dose equivalent due to radon in offices has been calculated to be 0.35 mSv y-1. Considering other sources of natural radiation, a rough estimate of the total annual equivalent dose of about 2.7 mSv for a person living in Hong Kong is obtained. Two simple methods are proposed to mitigate the radon hazard in offices: (1) the provision of smoke-free environments and (2) switching on the air conditioners earlier. The first method reduces the equivalent dose by about 0.13 mSv y-1 while the second reduces by about 0.1 mSv y-1, which can be regarded as significant. [ABSTRACT FROM AUTHOR]
Databáze: Supplemental Index