Uniform-fill nozzles for long-implosion-time prs experiments.

Autor: Levine, J., Coleman, P., Failor, B., Fisher, A., Lam, S. K., Riordan, J., Song, Y., Sze, H. M., Apruzese, J., Cochran, F., Davis, J., Moosman, B., Thornhill, J., Velikovich, A. L., Weber, B., Whitney, K. G., Coverdale, C., Deeney, C., McGurn, J., Bell, D.
Zdroj: 2000 13th International Conference on High-Power Particle Beams; 1/ 1/2000, p438-441, 4p
Abstrakt: We have developed uniform-fill nozzles for long-implosion PRS experiments to produce argon K-shell x-rays (photon energy > 3.1 keV). With a 7 cm diameter nozzle, which is appropriate for a 200 ns driver, we have achieved a stable implosion at 180 ns and 4 MA with peak argon K-shell yields exceeding 15 kJ. As previously seen with short (∼100 ns) implosion times, the K-shell yield scales as the fourth power of peak current, I4. Limited testing with a 10 cm nozzle, which is appropriate for a >250 ns driver, has also achieved a stable implosion. [ABSTRACT FROM PUBLISHER]