Autor: |
Reichle, R., Brichard, B., Pocheau, C., Jouve, M., van Ierschot, S., Martinez, S., Ooms, H., Berghmans, F., Decréton, M. |
Předmět: |
|
Zdroj: |
AIP Conference Proceedings; 3/12/2008, Vol. 988 Issue 1, p375-382, 8p, 1 Diagram, 9 Graphs |
Abstrakt: |
In the course of the development of a concept for a spectrally resolving infrared thermography diagnostic for the ITER divertor we have tested 3 types of infrared (IR) fibres in Co60 irradiation facilities under γ irradiation. The fibres were ZrF4 (and HfF4) fibres from different manufacturers, hollow fibres (silica capillaries with internal Ag/AgJ coating) and a sapphire fibre. For the IR range, only the latter fibre type encourages to go further for neutron tests in a reactor. If one restricted the interest onto the near infrared range, high purity core silica fibres could be used. This study might be seen as a typical example of the relation between diagnostic development for a nuclear environment and irradiation experiments. [ABSTRACT FROM AUTHOR] |
Databáze: |
Complementary Index |