Autor: |
Kumar, Dinesh, Sagar, Satyendu, Babita, Narain, Priyanka, Soni, Rashmi, Kumar, Sanjay, Kumar, Rajesh, Kumar, Ajay, Srivastva, R. k., Singh, Snigdha |
Předmět: |
|
Zdroj: |
European Journal of Cardiovascular Medicine; 2024, Vol. 14 Issue 1, p520-522, 3p |
Abstrakt: |
Objective: The aim of present study was conducted to evaluate the rapid immunochromatographic tests that detect NS1antigen, IgM, IgG antibody simultaneously and their comparative study by IgM capture Elisa. Material and methods: A total of 368 clinically diagnosed patients of dengue fever were included in the study. From all the patients 368 blood samples were collected and serum were separated. From all the serum tests were performed by rapid immunochromatographic test kit which can detect all three parameter NS1Ag, IgM& IgG antibody according to packet insert by manufacturers guide lines. All the tests were compared by IgM capture Elisa. Result: Out of368 blood samples of dengue fever 136 samples were positive by rapid immunochromatographic test. Among 136 positive cases 127 cases were NS1Ag positive, 05 cases are IgM reactive; 03 samples are IgG reactive and only 01 samples are reactive forNS1, IgM & IgG. Out of 368 blood samples tested by dengue Ig M capture Elisa only 123cases (33.42%) were reactive. Conclusion: Detection of dengue NS1Ag in the patient can be used as screening test in early cases of dengue illness. Since it is easy to perform it can be used in primary health care centres to take appropriate measure to reduce morbidity and mortality. Early notification of disease can awake the public health authority to take control measures. [ABSTRACT FROM AUTHOR] |
Databáze: |
Complementary Index |