Autor: |
Cardona-Hernandez, Roque, Schwandt, Anke, Alkandari, Hessa, Bratke, Heiko, Chobot, Agata, Coles, Nicole, Corathers, Sarah, Goksen, Damla, Goss, Peter, Imane, Zineb, Nagl, Katrin, O'Riordan, Stephen M.P., Jefferies, Craig, SWEET Study Group |
Předmět: |
|
Zdroj: |
Diabetes Care; May2021, Vol. 44 Issue 5, p1176-1184, 9p |
Abstrakt: |
Objective: Insulin delivery methods, glucose-monitoring modalities, and related outcomes were examined in a large, international, diverse cohort of children and adolescents with type 1 diabetes from the Better Control in Pediatric and Adolescent Diabetes: Working to Create Centers of Reference (SWEET) -Registry.Research Design and Methods: Participants with type 1 diabetes of ≥1 year, aged ≤18 years, and who had documented pump or sensor usage during the period August 2017-July 2019 were stratified into four categories: injections-no sensor (referent); injections + sensor; pump-no sensor; and pump + sensor. HbA1c and proportion of patients with diabetic ketoacidosis (DKA) or severe hypoglycemia (SH) were analyzed; linear and logistic regression models adjusted for demographics, region, and gross domestic product per capita were applied.Results: Data of 25,654 participants were analyzed. The proportions of participants (adjusted HbA1c data) by study group were as follows: injections-no sensor group, 37.44% (8.72; 95% CI 8.68-8.75); injections + sensor group, 14.98% (8.30; 95% CI 8.25-8.35); pump-no sensor group, 17.22% (8.07; 95% CI 8.03-8.12); and pump + sensor group, 30.35% (7.81; 95% CI 7.77-7.84). HbA1c was lower in all categories of participants who used a pump and/or sensor compared with the injections-no sensor treatment method (P < 0.001). The proportion of DKA episodes was lower in participants in the pump + sensor (1.98%; 95% CI 1.64-2.48; P < 0.001) and the pump-no sensor (2.02%; 95% CI 1.64-2.48; P < 0.05) groups when compared with those in the injections-no sensor group (2.91%; 95% CI 2.59-3.31). The proportion of participants experiencing SH was lower in pump-no sensor group (1.10%; 95% CI 0.85-1.43; P < 0.001) but higher in the injections + sensor group (4.25%; 95% CI 3.65-4.95; P < 0.001) compared with the injections-no sensor group (2.35%; 95% CI 2.04-2.71).Conclusions: Lower HbA1c and fewer DKA episodes were observed in participants using either a pump or continuous glucose monitoring (CGM) or both. Pump use was associated with a lower rate of SH. Across SWEET centers, use of pumps and CGM is increasing. The concomitant use of pump and CGM was associated with an additive benefit. [ABSTRACT FROM AUTHOR] |
Databáze: |
Complementary Index |
Externí odkaz: |
|