Testing preload responsiveness by the tidal volume challenge assessed by the photoplethysmographic perfusion index.

Autor: Bruscagnin C; AP-HP, Service de médecine intensive-réanimation, Hôpital de Bicêtre, DMU 4 CORREVE, Inserm UMR S_999, FHU SEPSIS, CARMAS, Université Paris-Saclay, 78 rue du Général Leclerc, 94270, Le Kremlin-Bicêtre, France.; Department of Anesthesia and Intensive Care B, Department of Surgery, Dentistry, Gynaecology and Pediatrics, University of Verona, AOUI-University Hospital Integrated Trust of Verona, Verona, Italy., Shi R; AP-HP, Service de médecine intensive-réanimation, Hôpital de Bicêtre, DMU 4 CORREVE, Inserm UMR S_999, FHU SEPSIS, CARMAS, Université Paris-Saclay, 78 rue du Général Leclerc, 94270, Le Kremlin-Bicêtre, France., Rosalba D; AP-HP, Service de médecine intensive-réanimation, Hôpital de Bicêtre, DMU 4 CORREVE, Inserm UMR S_999, FHU SEPSIS, CARMAS, Université Paris-Saclay, 78 rue du Général Leclerc, 94270, Le Kremlin-Bicêtre, France., Fouqué G; AP-HP, Service de médecine intensive-réanimation, Hôpital de Bicêtre, DMU 4 CORREVE, Inserm UMR S_999, FHU SEPSIS, CARMAS, Université Paris-Saclay, 78 rue du Général Leclerc, 94270, Le Kremlin-Bicêtre, France., Hagry J; AP-HP, Service de médecine intensive-réanimation, Hôpital de Bicêtre, DMU 4 CORREVE, Inserm UMR S_999, FHU SEPSIS, CARMAS, Université Paris-Saclay, 78 rue du Général Leclerc, 94270, Le Kremlin-Bicêtre, France., Lai C; AP-HP, Service de médecine intensive-réanimation, Hôpital de Bicêtre, DMU 4 CORREVE, Inserm UMR S_999, FHU SEPSIS, CARMAS, Université Paris-Saclay, 78 rue du Général Leclerc, 94270, Le Kremlin-Bicêtre, France., Donadello K; Department of Anesthesia and Intensive Care B, Department of Surgery, Dentistry, Gynaecology and Pediatrics, University of Verona, AOUI-University Hospital Integrated Trust of Verona, Verona, Italy., Pham T; AP-HP, Service de médecine intensive-réanimation, Hôpital de Bicêtre, DMU 4 CORREVE, Inserm UMR S_999, FHU SEPSIS, CARMAS, Université Paris-Saclay, 78 rue du Général Leclerc, 94270, Le Kremlin-Bicêtre, France.; Equipe d'Epidémiologie respiratoire intégrative, Centre de Recherche en Epidémiologie et Santé des Populations, Université Paris-Saclay, UVSQ, Univ. Paris-Sud, Inserm U1018, Villejuif, France., Teboul JL; AP-HP, Service de médecine intensive-réanimation, Hôpital de Bicêtre, DMU 4 CORREVE, Inserm UMR S_999, FHU SEPSIS, CARMAS, Université Paris-Saclay, 78 rue du Général Leclerc, 94270, Le Kremlin-Bicêtre, France., Monnet X; AP-HP, Service de médecine intensive-réanimation, Hôpital de Bicêtre, DMU 4 CORREVE, Inserm UMR S_999, FHU SEPSIS, CARMAS, Université Paris-Saclay, 78 rue du Général Leclerc, 94270, Le Kremlin-Bicêtre, France. xavier.monnet@aphp.fr.
Jazyk: angličtina
Zdroj: Critical care (London, England) [Crit Care] 2024 Sep 16; Vol. 28 (1), pp. 305. Date of Electronic Publication: 2024 Sep 16.
DOI: 10.1186/s13054-024-05085-w
Abstrakt: Background: To detect preload responsiveness in patients ventilated with a tidal volume (Vt) at 6 mL/kg of predicted body weight (PBW), the Vt-challenge consists in increasing Vt from 6 to 8 mL/kg PBW and measuring the increase in pulse pressure variation (PPV). However, this requires an arterial catheter. The perfusion index (PI), which reflects the amplitude of the photoplethysmographic signal, may reflect stroke volume and its respiratory variation (pleth variability index, PVI) may estimate PPV. We assessed whether Vt-challenge-induced changes in PI or PVI could be as reliable as changes in PPV for detecting preload responsiveness defined by a PLR-induced increase in cardiac index (CI) ≥ 10%.
Methods: In critically ill patients ventilated with Vt = 6 mL/kg PBW and no spontaneous breathing, haemodynamic (PICCO 2 system) and photoplethysmographic (Masimo-SET technique, sensor placed on the finger or the forehead) data were recorded during a Vt-challenge and a PLR test.
Results: Among 63 screened patients, 21 (33%) were excluded because of an unstable PI signal and/or atrial fibrillation and 42 were included. During the Vt-challenge in the 16 preload responders, CI decreased by 4.8 ± 2.8% (percent change), PPV increased by 4.4 ± 1.9% (absolute change), PI finger decreased by 14.5 ± 10.7% (percent change), PVI finger increased by 1.9 ± 2.6% (absolute change), PI forehead decreased by 18.7 ± 10.9 (percent change) and PVI forehead increased by 1.0 ± 2.5 (absolute change). All these changes were larger than in preload non-responders. The area under the ROC curve (AUROC) for detecting preload responsiveness was 0.97 ± 0.02 for the Vt-challenge-induced changes in CI (percent change), 0.95 ± 0.04 for the Vt-challenge-induced changes in PPV (absolute change), 0.98 ± 0.02 for Vt-challenge-induced changes in PI forehead (percent change) and 0.85 ± 0.05 for Vt-challenge-induced changes in PI finger (percent change) (p = 0.04 vs. PI forehead ). The AUROC for the Vt-challenge-induced changes in PVI forehead and PVI finger was significantly larger than 0.50, but smaller than the AUROC for the Vt-challenge-induced changes in PPV.
Conclusions: In patients under mechanical ventilation with no spontaneous breathing and/or atrial fibrillation, changes in PI detected during Vt-challenge reliably detected preload responsiveness. The reliability was better when PI was measured on the forehead than on the fingertip. Changes in PVI during the Vt-challenge also detected preload responsiveness, but with lower accuracy.
(© 2024. The Author(s).)
Databáze: MEDLINE