Gross morphology and morphometry of native and decellularized heart valves of caprine: A comparative study.

Autor: Sarma SAVM; Department of Veterinary Anatomy, Guru Angad Dev Veterinary and Animal Sciences University, Ludhiana, India., Pathak D; Department of Veterinary Anatomy, Guru Angad Dev Veterinary and Animal Sciences University, Ludhiana, India., Singh O; Department of Veterinary Anatomy, Guru Angad Dev Veterinary and Animal Sciences University, Ludhiana, India., Uppal V; Department of Veterinary Anatomy, Guru Angad Dev Veterinary and Animal Sciences University, Ludhiana, India., Mohindroo J; Department of Veterinary Surgery and Radiology, Guru Angad Dev Veterinary and Animal Sciences University, Ludhiana, India., Choudhary RK; College of Animal Biotechnology, Guru Angad Dev Veterinary and Animal Sciences University, Ludhiana, India.
Jazyk: angličtina
Zdroj: Anatomia, histologia, embryologia [Anat Histol Embryol] 2024 Jul; Vol. 53 (4), pp. e13075.
DOI: 10.1111/ahe.13075
Abstrakt: The gross morphological examination of native caprine heart valves revealed distinctive structural characteristics of the caprine's cardiac anatomy. Four primary orifices were identified, each protected by thin, valve-like structures. Atrioventricular orifices featured tricuspid and bicuspid valves, while the aorta and pulmonary arteries were guarded by semilunar valves. Within the atrioventricular apparatus, distinct features were observed including the tricuspid valve's three leaflets and the bicuspid valve's anterior and posterior leaflets. Ultrasonography provided insights into valve thickness and chordae tendineae lengths. Morphometric studies compared leaflets/cusps within individual native valves, showcasing significant variations in dimensions. Comparative analysis between native and decellularized valves highlighted the effects of decellularization on leaflet thickness and chordae tendineae lengths. Decellularized valves exhibited reduced dimensions compared to native valves, indicating successful removal of cellular components. While some dimensions remained unchanged post-decellularization, significant reductions were observed in leaflet thicknesses and chordae tendineae lengths. Notably, semilunar valve cusps displayed varying responses to decellularization, with significant reductions in cusp lengths observed in the aortic valve, while the pulmonary valve exhibited more subtle changes. These findings underscore the importance of understanding structural alterations in heart valves post-decellularization, providing valuable insights for tissue engineering applications and regenerative medicine.
(© 2024 Wiley‐VCH GmbH. Published by John Wiley & Sons Ltd.)
Databáze: MEDLINE