Simplifying the use of the Kiwi vacuum.

Autor: Skehan M; Department of Obstetrics and Gynaecology, University of Limerick Maternity Hospital, Limerick, Ireland.
Jazyk: angličtina
Zdroj: International journal of gynaecology and obstetrics: the official organ of the International Federation of Gynaecology and Obstetrics [Int J Gynaecol Obstet] 2024 Aug; Vol. 166 (2), pp. 551-558. Date of Electronic Publication: 2024 Jan 11.
DOI: 10.1002/ijgo.15295
Abstrakt: A simplified and easily teachable method of performing Kiwi vacuums is described. The Kiwi Omnicup has several features which make it the ideal instrument for correcting malposition. Once the correct position of the fetus is ascertained using ultrasound, it is always possible to maneuver the cup over the flexion point. A retrospective study was undertaken of 239 consecutive patients in the author's private practice requiring assisted delivery from 2010 until 2016. No case was declined. Successful Kiwi vacuum delivery was achieved in 233 cases (98%) and complication rates were low.
(© 2024 The Authors. International Journal of Gynecology & Obstetrics published by John Wiley & Sons Ltd on behalf of International Federation of Gynecology and Obstetrics.)
Databáze: MEDLINE