Measurement of energy and directional distribution of neutron ambient dose equivalent for the 7 Li(p,n) 7 Be reaction.

Autor: Roy AS; Health Physics Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085, India; Homi Bhabha National Institute, Training School Complex, Anushakti Nagar, Mumbai 400094, India., Banerjee K; Homi Bhabha National Institute, Training School Complex, Anushakti Nagar, Mumbai 400094, India; Variable Energy Cyclotron Centre, 1/AF, Bidhannagar, Kolkata 700064, India. Electronic address: kaushik@vecc.gov.in., Roy P; Homi Bhabha National Institute, Training School Complex, Anushakti Nagar, Mumbai 400094, India; Variable Energy Cyclotron Centre, 1/AF, Bidhannagar, Kolkata 700064, India., Shil R; Visva Bharati University, Santiniketan, Bolpur, West Bengal 731235, India., Ravishankar R; Health Physics Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085, India., Datta R; Homi Bhabha National Institute, Training School Complex, Anushakti Nagar, Mumbai 400094, India; RP&AD, Bhabha Atomic Research Centre, Trombay, Mumbai 400085, India., Sen A; Homi Bhabha National Institute, Training School Complex, Anushakti Nagar, Mumbai 400094, India; Variable Energy Cyclotron Centre, 1/AF, Bidhannagar, Kolkata 700064, India., Manna S; Homi Bhabha National Institute, Training School Complex, Anushakti Nagar, Mumbai 400094, India; Variable Energy Cyclotron Centre, 1/AF, Bidhannagar, Kolkata 700064, India., Ghosh TK; Homi Bhabha National Institute, Training School Complex, Anushakti Nagar, Mumbai 400094, India; Variable Energy Cyclotron Centre, 1/AF, Bidhannagar, Kolkata 700064, India., Mukherjee G; Homi Bhabha National Institute, Training School Complex, Anushakti Nagar, Mumbai 400094, India; Variable Energy Cyclotron Centre, 1/AF, Bidhannagar, Kolkata 700064, India., Rana TK; Homi Bhabha National Institute, Training School Complex, Anushakti Nagar, Mumbai 400094, India; Variable Energy Cyclotron Centre, 1/AF, Bidhannagar, Kolkata 700064, India., Kundu S; Homi Bhabha National Institute, Training School Complex, Anushakti Nagar, Mumbai 400094, India; Variable Energy Cyclotron Centre, 1/AF, Bidhannagar, Kolkata 700064, India., Nayak SS; Homi Bhabha National Institute, Training School Complex, Anushakti Nagar, Mumbai 400094, India; Variable Energy Cyclotron Centre, 1/AF, Bidhannagar, Kolkata 700064, India., Pandey R; Variable Energy Cyclotron Centre, 1/AF, Bidhannagar, Kolkata 700064, India., Paul D; Homi Bhabha National Institute, Training School Complex, Anushakti Nagar, Mumbai 400094, India; Variable Energy Cyclotron Centre, 1/AF, Bidhannagar, Kolkata 700064, India., Atreya K; Homi Bhabha National Institute, Training School Complex, Anushakti Nagar, Mumbai 400094, India; Variable Energy Cyclotron Centre, 1/AF, Bidhannagar, Kolkata 700064, India., Basu S; Homi Bhabha National Institute, Training School Complex, Anushakti Nagar, Mumbai 400094, India; Variable Energy Cyclotron Centre, 1/AF, Bidhannagar, Kolkata 700064, India., Mukhopadhyay S; Homi Bhabha National Institute, Training School Complex, Anushakti Nagar, Mumbai 400094, India; Variable Energy Cyclotron Centre, 1/AF, Bidhannagar, Kolkata 700064, India., Pandit D; Homi Bhabha National Institute, Training School Complex, Anushakti Nagar, Mumbai 400094, India; Variable Energy Cyclotron Centre, 1/AF, Bidhannagar, Kolkata 700064, India., Kulkarni MS; Health Physics Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085, India; Homi Bhabha National Institute, Training School Complex, Anushakti Nagar, Mumbai 400094, India., Bhattacharya C; Homi Bhabha National Institute, Training School Complex, Anushakti Nagar, Mumbai 400094, India; Variable Energy Cyclotron Centre, 1/AF, Bidhannagar, Kolkata 700064, India.
Jazyk: angličtina
Zdroj: Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine [Appl Radiat Isot] 2024 Feb; Vol. 204, pp. 111140. Date of Electronic Publication: 2023 Dec 04.
DOI: 10.1016/j.apradiso.2023.111140
Abstrakt: Double differential neutron fluence distributions were measured in the 7 Li(p,n) 7 Be reaction for proton beam energies 7, 9 and 12 MeV. Seven liquid scintillator based detectors were employed to measure neutron fluence distributions using the Time of Flight technique. Neutron ambient dose equivalents were determined from the measured fluence distribution using ICRP (International Commission on Radiological Protection) recommended fluence to dose equivalent conversion coefficients. Neutron dose equivalents were also measured using a conventional BF 3 detector based REM counter. Ambient dose equivalent measured by the REM counter is found to be in agreement with that determined from the neutron fluence spectra within their uncertainties. Angular distributions of the ambient dose equivalents were also determined from the measured fluence distributions at different angles.
Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
(Copyright © 2023 Elsevier Ltd. All rights reserved.)
Databáze: MEDLINE