Heart rate processing algorithms and exercise duration on reliability and validity decisions in biceps-worn Polar Verity Sense and OH1 wearables.

Autor: Navalta JW; Department of Kinesiology and Nutrition Sciences, University of Nevada, Las Vegas, Las Vegas, NV, USA. james.navalta@unlv.edu., Davis DW; Interdisciplinary Health Sciences, University of Nevada, Las Vegas, Las Vegas, NV, USA., Malek EM; Interdisciplinary Health Sciences, University of Nevada, Las Vegas, Las Vegas, NV, USA., Carrier B; Interdisciplinary Health Sciences, University of Nevada, Las Vegas, Las Vegas, NV, USA., Bodell NG; Department of Kinesiology, California State University, San Bernardino, San Bernardino, CA, USA., Manning JW; Department of Kinesiology and Outdoor Recreation, Southern Utah University, Cedar City, UT, USA., Cowley J; Department of Kinesiology and Outdoor Recreation, Southern Utah University, Cedar City, UT, USA., Funk M; Department of Kinesiology and Outdoor Recreation, Southern Utah University, Cedar City, UT, USA., Lawrence MM; Department of Kinesiology and Outdoor Recreation, Southern Utah University, Cedar City, UT, USA., DeBeliso M; Department of Kinesiology and Outdoor Recreation, Southern Utah University, Cedar City, UT, USA.
Jazyk: angličtina
Zdroj: Scientific reports [Sci Rep] 2023 Jul 20; Vol. 13 (1), pp. 11736. Date of Electronic Publication: 2023 Jul 20.
DOI: 10.1038/s41598-023-38329-w
Abstrakt: Consumer wearable technology use is widespread and there is a need to validate measures obtained in uncontrolled settings. Because no standard exists for the treatment of heart rate data during exercise, the effect of different approaches on reliability (Coefficient of Variation [CV], Intraclass Correlation Coefficient [ICC]) and validity (Mean Absolute Percent Error [MAPE], Lin's Concordance Correlation Coefficient [CCC)] were determined in the Polar Verity Sense and OH1 during trail running. The Verity Sense met the reliability (CV < 5%, ICC > 0.7) and validity thresholds (MAPE < 5%, CCC > 0.9) in all cases. The OH1 met reliability thresholds in all cases except entire session average (ICC = 0.57). The OH1 met the validity MAPE threshold in all cases (3.3-4.1%), but not CCC (0.6-0.86). Despite various heart rate data processing methods, the approach may not affect reliability and validity interpretation provided adequate data points are obtained. It is also possible that a large volume of data will artificially inflate metrics.
(© 2023. The Author(s).)
Databáze: MEDLINE
Nepřihlášeným uživatelům se plný text nezobrazuje