Accuracy of wristwatch-type photoplethysmography in detecting atrial fibrillation in daily life .
Autor: | Nonoguchi NM; Division of Cardiovascular Medicine, Kyorin University, 6-20-2 Shinkawa, Mitaka-City, Tokyo 181-8611, Japan., Soejima K; Division of Cardiovascular Medicine, Kyorin University, 6-20-2 Shinkawa, Mitaka-City, Tokyo 181-8611, Japan., Goda A; Division of Cardiovascular Medicine, Kyorin University, 6-20-2 Shinkawa, Mitaka-City, Tokyo 181-8611, Japan., Nishimura K; Statistics and Data Analysis, National Cerebral and Cardiovascular Center Research Institute, 6-1 Kishibe-Shimmachi, Suita, Osaka 564-8565, Japan., Onozuka D; Statistics and Data Analysis, National Cerebral and Cardiovascular Center Research Institute, 6-1 Kishibe-Shimmachi, Suita, Osaka 564-8565, Japan., Fujita S; Device Application Development Department, Fujimi Plant, Seiko Epson Corporation, 281 Fujimi, Fujimi-machi, Suwa-gun, Nagano 399-0293, Japan., Koyama F; Device Application Development Department, Fujimi Plant, Seiko Epson Corporation, 281 Fujimi, Fujimi-machi, Suwa-gun, Nagano 399-0293, Japan., Takano Y; Device Application Development Department, Fujimi Plant, Seiko Epson Corporation, 281 Fujimi, Fujimi-machi, Suwa-gun, Nagano 399-0293, Japan., Iguchi S; Nursing Department, Kyorin University Hospital, 6-20-2 Shinkawa, Mitaka-City, Tokyo 181-8611, Japan., Sato H; Clinical Laboratory Department, Kyorin University Hospital, 6-20-2 Shinkawa, Mitaka-City, Tokyo 181-8611, Japan., Mohri T; Division of Cardiovascular Medicine, Kyorin University, 6-20-2 Shinkawa, Mitaka-City, Tokyo 181-8611, Japan., Katusme Y; Division of Cardiovascular Medicine, Kyorin University, 6-20-2 Shinkawa, Mitaka-City, Tokyo 181-8611, Japan., Tashiro M; Division of Cardiovascular Medicine, Kyorin University, 6-20-2 Shinkawa, Mitaka-City, Tokyo 181-8611, Japan., Hoshida K; Division of Cardiovascular Medicine, Kyorin University, 6-20-2 Shinkawa, Mitaka-City, Tokyo 181-8611, Japan., Miwa Y; Division of Cardiovascular Medicine, Kyorin University, 6-20-2 Shinkawa, Mitaka-City, Tokyo 181-8611, Japan., Togashi I; Division of Advanced Arrhythmia Management, Kyorin University, 6-20-2 Shinkawa, Mitaka-City, Tokyo 181-8611, Japan., Ueda A; Division of Advanced Arrhythmia Management, Kyorin University, 6-20-2 Shinkawa, Mitaka-City, Tokyo 181-8611, Japan., Sato T; Division of Advanced Arrhythmia Management, Kyorin University, 6-20-2 Shinkawa, Mitaka-City, Tokyo 181-8611, Japan., Kohno T; Division of Cardiovascular Medicine, Kyorin University, 6-20-2 Shinkawa, Mitaka-City, Tokyo 181-8611, Japan. |
---|---|
Jazyk: | angličtina |
Zdroj: | European heart journal. Digital health [Eur Heart J Digit Health] 2022 Aug 16; Vol. 3 (3), pp. 455-464. Date of Electronic Publication: 2022 Aug 16 (Print Publication: 2022). |
DOI: | 10.1093/ehjdh/ztac041 |
Abstrakt: | Aims: Detection of asymptomatic paroxysmal atrial fibrillation is challenging. Smartphone- or smartwatch-based photoplethysmography is efficient at detecting irregular rhythms using pulse waves but is too complex for older patients. We aimed to evaluate the detection accuracy of atrial fibrillation by a wristwatch-type continuous pulse wave monitor (PWM) in daily life. Methods and Results: Patients at high risk of atrial fibrillation but with no history of atrial fibrillation ( n = 163; mean CHADS Conclusion: The wristwatch-type PWM has shown feasibility in detecting atrial fibrillation in daily life and showed the possibility of being used as a screening tool. Competing Interests: Conflict of interest: None declared. (© The Author(s) 2022. Published by Oxford University Press on behalf of the European Society of Cardiology.) |
Databáze: | MEDLINE |
Externí odkaz: |