Autor: van Riel LAMJG; Department of Urology, 26066Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, the Netherlands.; Department of Biomedical Engineering and Physics, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, the Netherlands., Swaan A; Department of Urology, 26066Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, the Netherlands.; Department of Biomedical Engineering and Physics, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, the Netherlands., Mannaerts CK; Department of Urology, 26066Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, the Netherlands., van Kollenburg RAA; Department of Urology, 26066Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, the Netherlands., Savci Heijink CD; Department of Pathology, 26066Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, the Netherlands., de Reijke TM; Department of Urology, 26066Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, the Netherlands., de Bruin DM; Department of Urology, 26066Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, the Netherlands.; Department of Biomedical Engineering and Physics, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, the Netherlands., Freund JE; Department of Pathology, 26066Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, the Netherlands.
Jazyk: angličtina
Zdroj: Technology in cancer research & treatment [Technol Cancer Res Treat] 2022 Jan-Dec; Vol. 21, pp. 15330338221093149.
DOI: 10.1177/15330338221093149
Abstrakt: Purpose: To assess the safety and technical feasibility of in-vivo needle-based forward-looking confocal laser endomicroscopy in prostate tissue. Methods: For this feasibility study, 2 patients with a suspicion of prostate cancer underwent transperineal needle-based confocal laser endomicroscopy during ultrasound-guided transperineal template mapping biopsies. After intravenous administration of fluorescein, needle-based confocal laser endomicroscopy imaging was performed with a forward-looking probe (outer diameter 0.9 mm) in 2 trajectories during a manual push-forward and pullback motion. A biopsy was taken in a coregistered parallel adjacent trajectory to the confocal laser endomicroscopy trajectory for histopathologic comparison. Peri- and postprocedural adverse events, confocal laser endomicroscopy device malfunction and procedural failures were recorded. Needle-based confocal laser endomicroscopy image quality assessment, image interpretation, and histology were performed by an experienced confocal laser endomicroscopy rater and uro-pathologist, blinded to any additional information. Results: In both patients, no peri- and post-procedural adverse events were reported following needle-based confocal laser endomicroscopy. No confocal laser endomicroscopy device malfunction nor procedural failures were reported. Within 1.5 min after intravenous administration of fluorescein, needle-based confocal laser endomicroscopy image quality was sufficient for interpretation for at least 14 min, yielding more than 5000 confocal laser endomicroscopy frames per patient. The pullback confocal laser endomicroscopy recordings and most of the push-forward recordings almost only visualized erythrocytes, being classified as non-representative. During the push-forward recordings, prostate tissue was occasionally visualized in single frames, insufficient for histopathologic comparison. Prostate carcinoma was identified by biopsy in one patient (Gleason score 4 + 3 = 7, >50%), while the biopsy from the other patient showed no malignancy. Conclusion: Needle-based confocal laser endomicroscopy imaging of in-vivo prostate tissue with a forward-looking confocal laser endomicroscopy probe is safe without device malfunctions or procedural failures. Needle-based confocal laser endomicroscopy is technically feasible, but the acquired confocal laser endomicroscopy datasets are non-representative. The confocal laser endomicroscopy images' non-representative nature is possibly caused by bleeding artifacts, movement artifacts and a lack of contact time with the tissue of interest. A different confocal laser endomicroscopy probe or procedure might yield representative images of prostatic tissue.
Databáze: MEDLINE