Evaluation of enamel loss by scanning electron microscopy after debonding brackets place with four different adhesives.

Autor: Rodríguez-Chávez JA; Departamento de Clínicas Odontologicas Integrales, Centro Universitario de Ciencias de la Salud, Universidad de Guadalajara, Salvador Quevedo y Zubieta 228, Guadalajara, Jalisco, 44340, Mexico., Arenas-Alatorre JÁ; Departamento de Materia Condensada, Instituto de Física, Universidad Nacional Autónoma de México, Circuito de la Investigación Científica S/N, Ciudad Universitaria, Delegación Coyoacán, Ciudad de México, 04510, Mexico., Flores-Ruiz HM; Departamento de Ciencias Naturales y Exactas, Universidad de Guadalajara, CUValles Campus, Carretera Guadalajara-Ameca Km 43.5, Ameca, Jalisco, 46600, Mexico., Flores-Ledesma A; Facultad de Estomatología, Benemerita Universidad Autónoma de Puebla, 31 Poniente #1304, Colonia Volcanes, Puebla, Puebla, 72410, Mexico., Aguilar-Pérez FJ; Facultad de Odontología, Campus de Ciencias de la Salud, Universidad Autónoma de Yucatán, Calle 61-A num 492-A, Centro, Mérida, Yucatán, 97000, Mexico.
Jazyk: angličtina
Zdroj: Microscopy research and technique [Microsc Res Tech] 2021 May; Vol. 84 (5), pp. 912-920. Date of Electronic Publication: 2020 Nov 26.
DOI: 10.1002/jemt.23652
Abstrakt: The clinically adequate shear bond strengths (SBS) should be from 2.8 to 10 MPa. The aim of this research is to observe tooth enamel loss through a scanning electron microscope (SEM) during the debonding of braces of four adhesive systems. Then, 100 premolars were used in 4 groups of 25 specimens each, for Transbond MIP (G1), Enlight (G2), Stylus (G3), and Transbond Plus SEP (G4). The research was done under the NOM ISO/TS 11405:2015. Gemini 3M were placed under the manufacturer's recommendations. The SBS test was done at 24 hr in an Instron electromechanical universal testing machine at 1 mm/1 min. Adhesive remnant index (ARI) was measured, all of the brackets where examined in the SEM. For the shear bonding strength G1 = 10.09 ± 2.73 MPa, G2 = 9.27 ± 3.99 MPa, G3 = 7.83 ± 4.46 MPa, and G4 = 6.40 ± 2.85 MPa statistically significant differences were found when comparing the four groups (p = .002). In the Tukey post hoc test, G1 versus G4 and G2 versus G4, statistically significant differences were found. For the ARI a value of 1 in 46%, followed by a value of 2 in 38%, a value of 3 in 13% and a value of 0 in 3% of the total samples, finding statistically significant differences (p < .001). In relation to the tooth enamel loss due to SBS, statistically significant differences were found (p = .326). G1 and G4 had not statistically significant differences. Even though our results concur with the appropriate clinical values, we observed tooth enamel loss with Transbond Plus SEP and Stylus.
(© 2020 Wiley Periodicals LLC.)
Databáze: MEDLINE