Hybrid cardiac imaging using PET/MRI: a joint position statement by the European Society of Cardiovascular Radiology (ESCR) and the European Association of Nuclear Medicine (EANM).

Autor: Nensa F; Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, 45147, Essen, Germany., Bamberg F; Department of Diagnostic and Interventional Radiology, University of Tuebingen, Hoppe-Seyler-Straße 3, 72076, Tübingen, Germany. fabian.bamberg@uni-tuebingen.de., Rischpler C; Department of Nuclear Medicine, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Straße 22, 81675, Munich, Germany., Menezes L; UCL Institute of Nuclear Medicine, and NIHR, University College London Hospitals Biomedical Research Centre, 5th Floor Tower, University College London Hospital, 235 Euston Road, London, NW1 2BU, UK., Poeppel TD; Klinik für Nuklearmedizin, Universitätsklinikum Essen, Hufelandstraße 55, 45122, Essen, Germany., la Fougère C; Nuklearmedizin und Klinische Molekulare Bildgebung, Otfried-Müller-Straße 14, 72076, Tübingen, Germany., Beitzke D; Department of Bioimaging and Image-Guided Therapy, Medical University Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria., Rasul S; Department of Radiology and Nuclear Medicine, Medical University Vienna, Währinger Gürtel 18-20, Floor 5L, 1090, Vienna, Austria., Loewe C; Department of Bioimaging and Image-Guided Therapy, Medical University Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria., Nikolaou K; Department of Diagnostic and Interventional Radiology, University of Tuebingen, Hoppe-Seyler-Straße 3, 72076, Tübingen, Germany., Bucerius J; Maastricht Oncology Centre, Medical University Maastricht, P. Debyelaan 25, 6229 HX, Maastrich, Netherlands., Kjaer A; Section of Endocrinology Research, University of Copenhagen, Panum Instituttet, Blegdamsvej 3, 2200, 12.3, Copenhagen N, Denmark., Gutberlet M; Diagnostic and Interventional Radiology, University of Leipzig-Heart Center, Strümpellstrasse 39, 04289, Leipzig, Germany., Prakken NH; University Medical Center Groningen, Department of Radiology, University of Groningen, Hanzeplein 1, 9713 GZ, Groningen, Netherlands., Vliegenthart R; University Medical Center Groningen, Department of Radiology, University of Groningen, Hanzeplein 1, 9713 GZ, Groningen, Netherlands., Slart RHJA; Department of Nuclear Medicine and Molecular, University Medical Center Groningen, Hanzeplein 1, P.O. Box 30.001, 9700 RB, Groningen, Netherlands., Nekolla SG; Department of Nuclear Medicine, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Straße 22, 81675, Munich, Germany., Lassen ML; Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, AKH-4L Währinger Gürtel 18-20, 1090, Vienna, Austria., Pichler BJ; Abteilung für Präklinische Bildgebung und Radiopharmazie, University of Tübingen, Röntgenweg 13, 72026, Tübingen, Germany., Schlosser T; Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstrasse 55, 45147, Essen, Germany., Jacquier A; Department of Cardiovascular and Thoracic Radiology, Assistance Publique Hopitaux de Marseille; University of Aix-Marseille, 264 rue Saint Pierre, 13385, Marseille, France., Quick HH; High-Field and Hybrid MR Imaging, University Hospital Essen, Hufelandstrasse 55, 45147, Essen, Germany., Schäfers M; Department of Nuclear Medicine and European Institute for Molecular Imaging (EIMI), University of Münster, Albert-Schweitzer-Campus 1, building A1, 48149, Münster, Germany., Hacker M; Division of Nuclear Medicine, Department of Biomedical Imaging and Image-guided Therapy, Medical University Vienna, Währinger Gürtel 18-20, Floor 5L, 1090, Vienna, Austria.
Jazyk: angličtina
Zdroj: European radiology [Eur Radiol] 2018 Oct; Vol. 28 (10), pp. 4086-4101. Date of Electronic Publication: 2018 May 02.
DOI: 10.1007/s00330-017-5008-4
Abstrakt: Positron emission tomography (PET) and magnetic resonance imaging (MRI) have both been used for decades in cardiovascular imaging. Since 2010, hybrid PET/MRI using sequential and integrated scanner platforms has been available, with hybrid cardiac PET/MR imaging protocols increasingly incorporated into clinical workflows. Given the range of complementary information provided by each method, the use of hybrid PET/MRI may be justified and beneficial in particular clinical settings for the evaluation of different disease entities. In the present joint position statement, we critically review the role and value of integrated PET/MRI in cardiovascular imaging, provide a technical overview of cardiac PET/MRI and practical advice related to the cardiac PET/MRI workflow, identify cardiovascular applications that can potentially benefit from hybrid PET/MRI, and describe the needs for future development and research. In order to encourage its wide dissemination, this article is freely accessible on the European Radiology and European Journal of Hybrid Imaging web sites.
Key Points: • Studies and case-reports indicate that PET/MRI is a feasible and robust technology. • Promising fields of application include a variety of cardiac conditions. • Larger studies are required to demonstrate its incremental and cost-effective value. • The translation of novel radiopharmaceuticals and MR-sequences will provide exciting new opportunities.
Databáze: MEDLINE