Reliability of Two Smartphone Applications for Radiographic Measurements of Hallux Valgus Angles.

Autor: Mattos E Dinato MC; Orthopedist, Foot and Ankle Division, Clinics Hospital, University of Campinas (UNICAMP), Campinas, Brazil; Orthopedist, Instituto Vita, São Paulo, Brazil., Freitas MF; Orthopedist, Instituto Vita, São Paulo, Brazil., Milano C; Orthopedist, Foot and Ankle Division, Clinics Hospital, University of Campinas (UNICAMP), Campinas, Brazil., Valloto E Jr; Orthopedist, Foot and Ankle Division, Hospital Nossa Senhora do Pari, São Paulo, Brazil., Ninomiya AF; Orthopedist, Foot and Ankle Division, Clinics Hospital, University of Campinas (UNICAMP), Campinas, Brazil., Pagnano RG; Assistant Professor, Department of Orthopaedics and Traumatology, Faculty of Medical Sciences, University of Campinas (UNICAMP), Campinas, Brazil. Electronic address: rpagnano@fcm.unicamp.br.
Jazyk: angličtina
Zdroj: The Journal of foot and ankle surgery : official publication of the American College of Foot and Ankle Surgeons [J Foot Ankle Surg] 2017 Mar - Apr; Vol. 56 (2), pp. 230-233.
DOI: 10.1053/j.jfas.2016.11.021
Abstrakt: The objective of the present study was to assess the reliability of 2 smartphone applications compared with the traditional goniometer technique for measurement of radiographic angles in hallux valgus and the time required for analysis with the different methods. The radiographs of 31 patients (52 feet) with a diagnosis of hallux valgus were analyzed. Four observers, 2 with >10 years' experience in foot and ankle surgery and 2 in-training surgeons, measured the hallux valgus angle and intermetatarsal angle using a manual goniometer technique and 2 smartphone applications (Hallux Angles and iPinPoint). The interobserver and intermethod reliability were estimated using intraclass correlation coefficients (ICCs), and the time required for measurement of the angles among the 3 methods was compared using the Friedman test. A very good or good interobserver reliability was found among the 4 observers measuring the hallux valgus angle and intermetatarsal angle using the goniometer (ICC 0.913 and 0.821, respectively) and iPinPoint (ICC 0.866 and 0.638, respectively). Using the Hallux Angles application, a very good interobserver reliability was found for measurements of the hallux valgus angle (ICC 0.962) and intermetatarsal angle (ICC 0.935) only among the more experienced observers. The time required for the measurements was significantly shorter for the measurements using both smartphone applications compared with the goniometer method. One smartphone application (iPinPoint) was reliable for measurements of the hallux valgus angles by either experienced or nonexperienced observers. The use of these tools might save time in the evaluation of radiographic angles in the hallux valgus.
(Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.)
Databáze: MEDLINE