A complication to remember: stitch sinus following laparoscopic umbilical hernia repair.

Autor: Rabiu AR; General Surgery Department, University Hospital Coventry and Warwickshire, Coventry, UK Rasheed.rabiu09@alumni.imperial.ac.uk., Tan LC; General Surgery Department, University Hospital Coventry and Warwickshire, Coventry, UK.
Jazyk: angličtina
Zdroj: Journal of surgical case reports [J Surg Case Rep] 2016 Aug 29; Vol. 2016 (8). Date of Electronic Publication: 2016 Aug 29.
DOI: 10.1093/jscr/rjw145
Abstrakt: This report describes a diagnostic dilemma and what we believe to be a previously unreported case of a stitch sinus caused by the presence of a non-absorbable centring suture used during laparoscopic mesh repair of an umbilical hernia. Successful treatment was achieved through umbilical excision and removal of the offending suture; the patient's recovery thereafter was uneventful. Surgeons should be aware of this complication when consenting patients and should consider the use of absorbable sutures to minimize such risk in similar procedures. In addition, clinicians may add this to their list of differential diagnoses in a patient presenting with pain, discharge or what appears to be a recurrence of their hernia following laparoscopic mesh repair of an umbilical hernia.
(Published by Oxford University Press and JSCR Publishing Ltd. All rights reserved. © The Author 2016.)
Databáze: MEDLINE