Assessment of coronary ischaemia by myocardial perfusion dipyridamole stress technetium-99 m tetrofosmin, single-photon emission computed tomography, and coronary angiography in children with Kawasaki disease: pre- and post-coronary bypass grafting.
Autor: | Mostafa MS; 1Department of Nuclear medicine,Assiut University,Egypt., Sayed AO; 2Department of Pediatrics,Children and Women's University Hospital,Minia University,P.O. Box 61519,El-Minia,Egypt., Al Said YM; 3Department of Nuclear Medicine,Cairo University,Egypt. |
---|---|
Jazyk: | angličtina |
Zdroj: | Cardiology in the young [Cardiol Young] 2015 Jun; Vol. 25 (5), pp. 927-34. Date of Electronic Publication: 2014 Aug 04. |
DOI: | 10.1017/S1047951114001292 |
Abstrakt: | Background: Coronary artery lesions in Kawasaki disease invasively assessed by coronary angiography. Evaluation of myocardial perfusion by single-photon emission computed tomography may identify the haemodynamic significance of coronary lesions. Objective: To evaluate diagnostic accuracy of dipyridamole stress technetium-99 m tetrofosmin, single-photon emission computed tomography as a possible alternative to invasive coronary angiography for detection and follow-up of myocardial ischaemia in patients with Kawasaki disease, and pre- and post-coronary bypass grafting. Patients and Methods: Coronary angiography and single-photon emission computed tomography were performed on 21 patients who were classified into three groups - group I (stenosis), group II (giant aneurysms), and group III (small aneurysms). Of the 21 patients, 16 (groups I and II) patients with myocardial perfusion defects, who underwent coronary bypass grafting, were followed up with single-photon emission computed tomography. Result: In group I, all patients had significant coronary stenosis and 100% of them had perfusion defects in the anterior and septal walls. In group II, all patients had giant aneurysms and 83% of them had inferior and inferolateral perfusion defects. In group III, all patients had small aneurysms and 100% of them had normal perfusion. Pre-coronary bypass grafting myocardial ischaemic defects disappeared in all patients after surgery. Sensitivity, specificity, and accuracy of single-photon emission computed tomography were 94, 100, and 95%, respectively. Conclusion: Technetium-99 m tetrofosmin single-photon emission computed tomography can be applied as an accurate non-invasive diagnostic technique for detecting myocardial perfusion defects with coronary artery lesions, and to show improved or even normalised perfusion of the myocardium in patients after surgical revascularisation. |
Databáze: | MEDLINE |
Externí odkaz: |