A model-based control protocol for transition from ICU to HDU: Robustness analysis.

Autor: Razak NN, Chase JG, Suhaimi FM, Shaw GM, Jamaluddin U
Jazyk: angličtina
Zdroj: Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference [Annu Int Conf IEEE Eng Med Biol Soc] 2013; Vol. 2013, pp. 205-8.
DOI: 10.1109/EMBC.2013.6609473
Abstrakt: The robustness of a model-based control protocol as a less intensive TGC protocol using insulin Glargine for provision of basal insulin is simulated in this study. To quantify the performance and robustness of the protocol to errors, namely physiological variability and sensor errors, an in-silico Monte Carlo analysis is performed. Actual patient data from Christchurch Hospital, New Zealand were used as virtual trial patients.
Databáze: MEDLINE