Accuracy of acromioclavicular joint injections.
Autor: | Wasserman BR; Winthrop Orthopaedic Associates, Winthrop University Hospital, Garden City, New York, USA., Pettrone S, Jazrawi LM, Zuckerman JD, Rokito AS |
---|---|
Jazyk: | angličtina |
Zdroj: | The American journal of sports medicine [Am J Sports Med] 2013 Jan; Vol. 41 (1), pp. 149-52. Date of Electronic Publication: 2012 Nov 27. |
DOI: | 10.1177/0363546512467010 |
Abstrakt: | Background: Injection to the acromioclavicular (AC) joint can be both diagnostic and therapeutic. Purpose: The purpose of this study was to evaluate the accuracy of in vivo AC joint injections. Study Design: Case series; Level of evidence, 4. Methods: Thirty patients with pain localized to the AC joint were injected with 1 mL of 1% lidocaine and 0.5 mL of radiographic contrast material (Isovue). Radiographs of the AC joint were taken after the injection. Each radiograph was reviewed by a musculoskeletal radiologist and graded as intra-articular, extra-articular, or partially intra-articular. Results: Of the 30 injections performed, 13 (43.3%) were intra-articular, 7 (23.3%) were partially articular, and 10 (33.3%) were extra-articular. When the intra-articular and the partially articular groups were combined, 20 patients (66.7%) had some contrast dye in the AC joint. Conclusion: This study demonstrates that despite the relatively superficial location of the AC joint, the clinical accuracy of AC joint injections remains relatively low. |
Databáze: | MEDLINE |
Externí odkaz: |