Accuracy of the second pour casts using dual-arch trays.
Autor: | Broilo JR; Pontificial Catholic University of Rio Grande do Sul, Av. Ipiranga 6681, Porto Alegre, Rio Grande do Sul, Brazil., Ghiggi PC, Borges GA, Burnett LH Jr, Spohr AM |
---|---|
Jazyk: | angličtina |
Zdroj: | Stomatologija [Stomatologija] 2011; Vol. 13 (1), pp. 15-8. |
Abstrakt: | Objective: To compare, in vitro, the accuracy between dental stone casts obtained from the first and the second pour using metallic (Smart) and plastic (Triple Tray) dual-arch trays. Material and Methods: The impressions were taken using Flexitime® vinyl polysiloxane from a typodont model with a mandibular right first molar prepared for a full crown. Ten impressions were made with each tray and poured using type IV die stone. After 1 hour, the casts were removed from the impressions and, 1-hour later, second pours were completed. The mesio-distal and the buccal-lingual widths at the gingival margin of the prepared tooth on the cast were measured in a perfil projector. The results were submitted to Student's t-test (α=0.05) using SPSS version 10.0. Results: There was a statistically significant difference between the first and second pours using the plastic tray in the mesio-distal width. Conclusion: It could be suggested that a repeated pour is more accurate using a metallic tray. |
Databáze: | MEDLINE |