[Filtering facepieces: effect of oily aerosol load on penetration through the filtering material].

Autor: Plebani C; ISPESL--Dipartimento Igiene del Lavoro, Laboratorio Dispositivi di Protezione--Monte Porzio Catone (RM). carmela.plebani@ispesl.it, Listrani S, Di Luigi M
Jazyk: italština
Zdroj: La Medicina del lavoro [Med Lav] 2010 Jul-Aug; Vol. 101 (4), pp. 293-302.
Abstrakt: Background: Electrostatic filters are widely used in applications requiring high filtration efficiency and low pressure drop. However various studies showed that the penetration through electrostatic filters increases during exposure to an aerosol flow.
Objectives: This study investigates the effects of prolonged exposure to an oily aerosol on the penetration through filtering facepieces available on the market.
Methods: Some samples of FFP1, FFP2 and FFP3 filtering facepieces were exposed for 8 hours consecutively to a paraffin oil polydisperse aerosol. At the end of the exposure about 830 mg of paraffin oil were deposited in the facepiece.
Results: All the examined facepieces showed penetration values that increased with paraffin oil load while pressure drop values were substantially the same before and after exposure. The measured maximum penetration values did not exceed the maximum penetration values allowed by the European technical standards, except in one case. According to the literature, 830 mg of oil load in a facepiece is not feasible in workplaces over an eight- hour shift. However, the trend of the penetration versus exposure mass suggests that if the load increases, the penetration may exceed the maximum allowed values. For comparison a mechanical filter was also studied. This showed an initial pressure drop higher than FFP2 filtering facepieces characterized by comparable penetration values. During exposure the pressure drop virtually doubled while penetration did not change.
Conclusions: The increase in penetration with no increase in pressure drop in the analyzed facepieces indicates that it is necessary to comply with the information supplied by the manufacturer that restricts their use to a single shift.