Does sampling site influence levels of free thyroxine and thyrotropin determined by a current immunoassay?

Autor: Rondeel JM; Isala Klinieken, Department of Clinical Chemistry, P.O. Box 10400, 8000 GK Zwolle, The Netherlands. j.rondeel@isala.nl, Albers JS, Schroor EJ, Schindhelm RK
Jazyk: angličtina
Zdroj: Clinical biochemistry [Clin Biochem] 2010 Jun; Vol. 43 (9), pp. 771-2. Date of Electronic Publication: 2010 Mar 27.
DOI: 10.1016/j.clinbiochem.2010.03.003
Abstrakt: Objectives: To examine the effect of sampling site on levels of free thyroxine (fT4) and thyrotropin (TSH).
Design and Methods: fT4 and TSH were determined by a current immuno-assay in paired samples of capillary and venous blood drawn from 30 euthyroid adults.
Results: Mean levels of fT4 and TSH did not differ significantly between capillary and venous blood; capillary and venous levels correlated well and did not differ significantly from unity.
Conclusions: Sampling site does not influence levels of fT4 and TSH.
(2010 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.)