Autor: |
Tumeh SS; Department of Radiology, Brigham & Women's Hospital, Boston, Massachusetts 02115., Carvalho PA, van den Abbeele AD, Maguire JH, Rauh DA, Neptune M, Kassis AI |
Jazyk: |
angličtina |
Zdroj: |
Journal of nuclear biology and medicine (Turin, Italy : 1991) [J Nucl Biol Med (1991)] 1991 Jan-Mar; Vol. 35 (1), pp. 4-9. |
Abstrakt: |
Eleven patients with suspected foci of inflammation and/or infection were scanned with 111In-labeled polyclonal human IgG. Seven patients were suspected of having the source of their infection in the abdomen, three in the musculoskeletal system and one in the thoracic aorta. The test was truly positive in seven patients, truly negative in three and falsely negative in one. All the true positive cases showed abnormally increased radiopharmaceutical uptake at the site of infection by six hours, suggesting the diagnosis, although the intensity of uptake increased progressively 24 hours later. There were no untoward effects noted in this series. This examination is potentially useful in the early depiction of focal sources of infection/inflammation. |
Databáze: |
MEDLINE |
Externí odkaz: |
|