Zobrazeno 1 - 10
of 58
pro vyhledávání: '"water equivalent path length"'
Autor:
Ozgur Ates, Fakhriddin Pirlepesov, Jinsoo Uh, Chia-ho Hua, Thomas E. Merchant, Andrew Boria, Andrew M. Davidoff, Dylan E. Graetz, Matthew J. Krasin
Publikováno v:
Cancers, Vol 16, Iss 3, p 642 (2024)
(1) Background: Proton therapy, a precise form of radiation treatment, can be significantly affected by variations in bowel content. The purpose was to identify the most beneficial gantry angles that minimize deviations from the treatment plan qualit
Externí odkaz:
https://doaj.org/article/40a2b7dc69f740a2892d7d296061fea1
Autor:
Ozgur Ates, Jinsoo Uh, Fakhriddin Pirlepesov, Chia-Ho Hua, Thomas E. Merchant, Matthew J. Krasin
Publikováno v:
Cancers, Vol 15, Iss 17, p 4200 (2023)
(1) Background: Synthetic CT images of the pelvis were generated from daily CBCT images to monitor changes in water equivalent path length (WEPL) and determine the dosimetric impact of anatomy changes along the proton beam’s path; (2) Methods: Ten
Externí odkaz:
https://doaj.org/article/ee03184ff93f40e38363a7ca267e3d8d
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Autor:
Carmen Seller Oria, Jeffrey Free, Gabriel Guterres Marmitt, Barbara Knäusl, Sytze Brandenburg, Antje C. Knopf, Arturs Meijers, Johannes A. Langendijk, Stefan Both
Publikováno v:
Medical Physics, 50(3), 1756-1765. Wiley
Background: Proton radiography (PR) uses highly energetic proton beams to create images where energy loss is the main contrast mechanism. Water-equivalent path length (WEPL) measurements using flat panel PR (FP-PR) have potential for in vivo range ve
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::e610c59ce95143d8e75a3027df5a1c09
https://research.rug.nl/en/publications/d46c42d0-d7a1-4b33-aea6-1e401fe4489f
https://research.rug.nl/en/publications/d46c42d0-d7a1-4b33-aea6-1e401fe4489f
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Autor:
Yang Kyun Park, Ludvig Paul Muren, Lei Dong, A.G. Andersen, Brian Winey, Jørgen B. B. Petersen, U.V. Elstrøm, Gregory C. Sharp
Publikováno v:
Physics and Imaging in Radiation Oncology, Vol 16, Iss, Pp 89-94 (2020)
Andersen, A G, Park, Y K, Elstrøm, U V, Petersen, J B B, Sharp, G C, Winey, B, Dong, L & Muren, L P 2020, ' Evaluation of an a priori scatter correction algorithm for cone-beam computed tomography based range and dose calculations in proton therapy ', Physics and Imaging in Radiation Oncology, vol. 16, pp. 89-94 . https://doi.org/10.1016/j.phro.2020.09.014
Andersen, A G, Park, Y K, Elstrøm, U V, Petersen, J B B, Sharp, G C, Winey, B, Dong, L & Muren, L P 2020, ' Evaluation of an a priori scatter correction algorithm for cone-beam computed tomography based range and dose calculations in proton therapy ', Physics and Imaging in Radiation Oncology, vol. 16, pp. 89-94 . https://doi.org/10.1016/j.phro.2020.09.014
Background and purpose Scatter correction of cone-beam computed tomography (CBCT) projections may enable accurate online dose-delivery estimations in photon and proton-based radiotherapy. This study aimed to evaluate the impact of scatter correction
Autor:
Kia Busch, Andreas Gravgaard Andersen, Jørgen Breede Baltzer Petersen, Stine Elleberg Petersen, Heidi S Rønde, Lise Nørgaard Bentzen, Sara Pilskog, Peter Sandegaard Skyt, Ole Nørrevang, Ludvig Paul Muren
Publikováno v:
Biomedical Engineering & Physics Express
Busch, K, Andersen, A G, Petersen, J B B, Petersen, S E, Rønde, H S, Bentzen, L, Pilskog, S, Skyt, P, Nørrevang, O & Muren, L P 2022, ' Towards range-guidance in proton therapy to detect organ motion-induced dose degradations ', Biomedical Physics & Engineering Express, vol. 8, no. 2, 025018 . https://doi.org/10.1088/2057-1976/ac5151
Busch, K, Andersen, A G, Petersen, J B B, Petersen, S E, Rønde, H S, Bentzen, L, Pilskog, S, Skyt, P, Nørrevang, O & Muren, L P 2022, ' Towards range-guidance in proton therapy to detect organ motion-induced dose degradations ', Biomedical Physics & Engineering Express, vol. 8, no. 2, 025018 . https://doi.org/10.1088/2057-1976/ac5151
Introduction: Internal organ motion and deformations may cause dose degradations in proton therapy (PT) that are challenging to resolve using conventional image-guidance strategies. This study aimed to investigate the potential of range guidance usin
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.