Zobrazeno 1 - 10
of 302
pro vyhledávání: '"transmission factor"'
Publikováno v:
e-Polymers, Vol 24, Iss 1, Pp 2544-53 (2024)
Based on the experimental and theoretical radiation attenuation, this study produced and tested a composite material made of polyester reinforced with SnO at varied concentrations and abbreviated as Pol-SnOx, where x = 0–60% with steps of 20 wt% Al
Externí odkaz:
https://doaj.org/article/f4f77e9be807421c8822a7245c4bc285
Publikováno v:
Nuclear Engineering and Technology, Vol 56, Iss 2, Pp 477-484 (2024)
Experimental investigations on gamma - rays attenuation parameters and dielectric spectroscopic properties were done on a polymeric mixture with chemical composition (100-x) polyethylene + x basalt, where x = 0, 1, 3, 5, 10, and 20 wt%. Using the mel
Externí odkaz:
https://doaj.org/article/b46db7f09047464eaa496cf678235fd8
Publikováno v:
Jixie chuandong, Vol 47, Pp 58-68 (2023)
According to the theory and method of topological design of the parallel mechanism (PM) based on position and orientation characteristic (POC) equations, a novel three-translation (3T) parallel mechanism for grasping is proposed. Firstly, the design
Externí odkaz:
https://doaj.org/article/f727932428c94afcaab242af346b504d
Publikováno v:
Open Chemistry, Vol 21, Iss 1, Pp 172-8 (2023)
The radiation attenuation characteristics of WO3-Li2O-ZnO-P2O5 glasses have been examined using Phy-X software. The linear attenuation coefficient is correspondingly increased with the inclusion of WO3, which indicates the existence of a reducing ten
Externí odkaz:
https://doaj.org/article/dd69963a253c446ca0ffef03a9b4731c
Autor:
Bahram R. Maleki
Publikováno v:
Nuclear Engineering and Technology, Vol 55, Iss 1, Pp 324-329 (2023)
Different types of deterministic solution methods were used to solve neutron transport equations corresponding to half-space and slab albedo problems. In these types of solution methods, in addition to the error of the numerical solutions, the obtain
Externí odkaz:
https://doaj.org/article/abebad0de9f44afc920884becd1f54c8
Publikováno v:
Radiation Oncology, Vol 17, Iss 1, Pp 1-9 (2022)
Abstract Background Monte Carlo simulation is considered as the most accurate method for dose calculation in radiotherapy. PRIMO is a Monte-Carlo program with a user-friendly graphical interface. Material and method A VitalBeam with 6MV and 6MV flatt
Externí odkaz:
https://doaj.org/article/748ff13ce4a54550bfe0feb1afccacc9
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Autor:
Ghada AlMisned, Duygu Sen Baykal, Erkan Ilik, Mohammed Abuzaid, Shams A.M. Issa, G. Kilic, Hesham M.H. Zakaly, Antoaneta Ene, H.O. Tekin
Publikováno v:
Heliyon, Vol 9, Iss 7, Pp e17838- (2023)
We report the functional assessment of tungsten (VI) oxide on gamma-ray attenuation properties of 60Sb2O3-(40-x)NaPO3-xWO3 antimony glasses. The elemental mass-fractions and glass-densities of each glass sample are specified separately for the MCNPX
Externí odkaz:
https://doaj.org/article/6a930caac5f0467f890f5816eaccde20
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.