Zobrazeno 1 - 10
of 178
pro vyhledávání: '"short-circuit impedance"'
Publikováno v:
Energies, Vol 17, Iss 15, p 3714 (2024)
Short-circuit impedance is an important economic and technical index to test the cost, efficiency and operation safety of transformers. Increasing the short-circuit impedance of the transformer can reduce the influence of the transformer fault curren
Externí odkaz:
https://doaj.org/article/23f16ed45f9847f591a42120e749d0af
Publikováno v:
Energies, Vol 17, Iss 7, p 1622 (2024)
In the context of carbon peaking and carbon neutrality goals, the integration of a large number of renewable energy sources may trigger significant tidal changes, leading to transmission congestion, wind and light abandonment, power oscillation, volt
Externí odkaz:
https://doaj.org/article/191f548f1a344d6ab36d33e36d420d01
Publikováno v:
Ingenius: Revista de Ciencia y Tecnología, Iss 30 (2023)
This article studies the location of faults in the electrical distribution system based on processing short-circuit signals. For this analysis, the simulation of cases using the CYME software is proposed, using the Wavelet transform to study the sign
Externí odkaz:
https://doaj.org/article/675edf2721614934bd59c9b1beb99976
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Publikováno v:
IEEE Access, Vol 8, Pp 223848-223858 (2020)
A staggered transformer of power frequency inverters in uninterruptible power supplies (UPS) can be used as both a voltage transformer and an inductance of filter circuits to replace a traditional reactor. In this paper, a method is presented to calc
Externí odkaz:
https://doaj.org/article/094c6ef2c5814251960765869849ef83
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Publikováno v:
IEEE Access, Vol 7, Pp 115273-115280 (2019)
Different from a three-winding transformer and ac passive filtering method, this paper proposes an inductive filtering (IF) method with a four-winding inductive filtering transformer (FW-IFT) for power system supplying nonlinear loads. Based on this,
Externí odkaz:
https://doaj.org/article/8c59d984c6624a529641a9624ccf45f0
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.