Zobrazeno 1 - 10
of 33
pro vyhledávání: '"safety needles"'
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Publikováno v:
Cureus
Purpose Current evidence indicates that diabetic patients' preference and medication adherence can be affected by the type of insulin pen needles. We aimed to assess the impact of insulin pen devices with safety needles (SPN) on the usability, behavi
Autor:
Ankur Modi, Keith Cryar
Publikováno v:
Journal of the Endocrine Society
Diabetic ketoacidosis is associated with a mortality rate of upto 6.1% and accounts for an estimated 115000 hospital discharges per year in the United States. In order to reduce mortality related to DKA, precipitating causes must be identified and ad
Publikováno v:
Cureus
Introduction The study intends to observe the frequency of preanalytical phase errors both inside and outside the clinical laboratory according to certain quality indicators (QIs). Methods The one-week observation focused on 73 nurses drawing blood f
Publikováno v:
Value in Health Regional Issues. 22:S58-S59
Autor:
Niamh Mitchell, Michael S. Valic, Jeffrey M. Karp, Eoin D. O'Cearbhaill, Peter T. Masiakos, Bryan Laulicht, Lawrence Yu
Publikováno v:
Med Devices Sens
Efficient and safe access to targeted therapeutic sites is a universal challenge in minimally invasive medical intervention. Percutaneous and transluminal needle insertion is often performed blindly and requires significant user skill and experience
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::6477c58f230f81ac6b74237f75d1f72d
Publikováno v:
A & A Case Reports. 5:131-133
In this report, we present a unique complication of hemodialysis: the hemodialysis access needle was lost into an arteriovenous fistula. The event went unnoticed for several months. The needle eventually migrated into the right ventricle, requiring a
Autor:
Bruno Ferraro, Alessandra Braus, Maurizio Destro, Sara Madaschi, Carmine S. Poerio, Estella M. Davis, Giovanni Veronesi, Paolo Sganzerla, Antonio Bossi, Lavinia Gilberti
Publikováno v:
Current Diabetes Reviews
Background: to assess costs and safety of insulin pen devices and safety needles as compared to vial/syringes in hospitalized patients requiring insulin therapy in a General Hospital in Northern Italy. Materials and Methods: in a prospective 9-month
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::1a5e73d3e5c26431744de142294bf0a5
http://hdl.handle.net/11383/2059387
http://hdl.handle.net/11383/2059387
Autor:
H. Mosnier-Pudar, Danielle Durain, Odile Lautier, Pierre Faure, Luminita Spinu, Sophie Gonbert
Publikováno v:
Insulin. 3:232-237
Background: Needlestick injuries among health care professionals are a costly problem, both economically and in terms of anxiety and stress. NovoFine® Autocover® (NFA) 30G safety needles (Novo Nordisk A/S, Bagsvaerd, Denmark) were designed to minim
Autor:
Alessandra Braus, Antonio Bossi, Carmine S. Poerio, Giovanni Veronesi, Estella M. Davis, Giovanni Meroni, Lavinia Gilberti, Maurizio Destro
Publikováno v:
Clinical Diabetes and Endocrinology
Background A paucity of data exists to examine nurses’ satisfaction with the use of insulin pens with safety needles in hospitalized patients with diabetes. We investigated major determinants of nurses’ preference of the method of insulin adminis