Zobrazeno 1 - 10
of 788
pro vyhledávání: '"oversensing"'
Publikováno v:
Journal of Arrhythmia, Vol 40, Iss 5, Pp 1210-1213 (2024)
Externí odkaz:
https://doaj.org/article/bafd28a9108e4529869d1839e9d2c07e
Publikováno v:
HeartRhythm Case Reports, Vol 10, Iss 9, Pp 601-604 (2024)
Externí odkaz:
https://doaj.org/article/1cf7175bc2ef463999aac0d857f2dbf4
Autor:
Maurizio Santomauro, Mario Petretta, Carla Riganti, Mario Alberto Santomauro, Mariarosaria De Luca, Andrea Santomauro, Antonio Cittadini
Publikováno v:
Monaldi Archives for Chest Disease (2024)
Subcutaneous implantable cardioverter-defibrillators (S-ICD) are effective in protecting patients against sudden death but expose them to a higher risk of inappropriate shock (IAS). We performed a systematic search of studies published between Janua
Externí odkaz:
https://doaj.org/article/53eb191b72944987853d1351392a6628
Oversensing caused by trapped air in the header of subcutaneous cardioverter‐defibrillator generator
Publikováno v:
Journal of Arrhythmia, Vol 39, Iss 5, Pp 803-806 (2023)
Externí odkaz:
https://doaj.org/article/edea63ddbfde43bb8ccf9f6b87255ff1
Autor:
Akihito Ideishi, Kenichiro Yamagata, Tatsuya Nishii, Hideto Miyanooi, Yuichiro Miyazaki, Akinori Wakamiya, Keiko Shimamoto, Nobuhiko Ueda, Kenzaburo Nakajima, Mitsuru Wada, Tsukasa Kamakura, Kohei Ishibashi, Yuko Inoue, Koji Miyamoto, Takashi Noda, Satoshi Nagase, Takeshi Aiba, Kengo Kusano
Publikováno v:
Journal of Arrhythmia, Vol 39, Iss 4, Pp 580-585 (2023)
Abstract Introduction Cardiac implantable electronic devices are used in patients with cardiac rhythm disorders. Computed tomography irradiation is not prohibited for patients with cardiac implantable electronic devices, despite adverse events being
Externí odkaz:
https://doaj.org/article/29d606924e0743219d62764accc99021
Autor:
Banveet Kaur Khetarpal, Awad Javaid, Justin Z. Lee, Fred Kusumoto, Siva K. Mulpuru, Dan Sorajja, Yong‐Mei Cha, Komandoor Srivathsan
Publikováno v:
Journal of Arrhythmia, Vol 39, Iss 2, Pp 198-206 (2023)
Abstract Background The incidence and impact of noise in a subcutaneous implantable cardioverter defibrillator (S‐ICD) after left ventricular assist device (LVAD) implantation is not well established. Methods We performed a retrospective study of p
Externí odkaz:
https://doaj.org/article/5659e9847d0b424fb4853e52c1a1a531
Autor:
Athanasios Saplaouras, Panagiotis Mililis, Ourania Kariki, George Bazoukis, Athena Batsouli, Vasileios Antonakos, Stylianos Dragasis, Ilias G. Patsiotis, Konstantinos P. Letsas, Michael Efremidis
Publikováno v:
Clinical Case Reports, Vol 11, Iss 10, Pp n/a-n/a (2023)
Key Clinical Message R‐wave double counting is a rare cause of ventricular oversensing that can lead to inappropriate shocks. Optimizing device programming is essential for the avoidance of subsequent inappropriate therapies. Abstract R‐wave doub
Externí odkaz:
https://doaj.org/article/f39bc132496f40679f2152e912653208
Autor:
Ayumi Omura, MD, Tatsuya Onuki, MD, PhD, Hiroshi Mase, MD, Masaaki Kurata, MD, PhD, Daisuke Wakatsuki, MD, PhD, Hiroshi Suzuki, MD, PhD
Publikováno v:
HeartRhythm Case Reports, Vol 8, Iss 9, Pp 606-609 (2022)
Externí odkaz:
https://doaj.org/article/85169e2ed8c64bb6ad1674afd3912161
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.