Zobrazeno 1 - 10
of 44
pro vyhledávání: '"longitudinal temperature distribution"'
Publikováno v:
Case Studies in Thermal Engineering, Vol 61, Iss , Pp 105132- (2024)
Previous research has commonly assumed that tunnel fire blockage occurs at the central longitudinal axis of tunnels. However, fires may arise at different points within tunnels, each with various distances from the tunnel sidewall. The study aimed to
Externí odkaz:
https://doaj.org/article/ee854c81dcea48de975d91088c28a99a
Publikováno v:
Case Studies in Thermal Engineering, Vol 59, Iss , Pp 104545- (2024)
In order to investigate the impact mechanism of branch slope on fire smoke in underground bifurcation spaces, a series of small-scale fire experiments were conducted. This study measured relevant data under natural ventilation conditions for four dif
Externí odkaz:
https://doaj.org/article/1a9e974423af4cc885cd322e40432119
Publikováno v:
Case Studies in Thermal Engineering, Vol 51, Iss , Pp 103651- (2023)
Extensive studies have focused on single-straight tunnels or subway bifurcation tunnel fire. However, the effect of large angle bifurcation on longitudinal maximum temperature rise attenuation in Urban Traffic Link Tunnel(UTLT)needs to be further
Externí odkaz:
https://doaj.org/article/e8b5b03a8d994af9810d128002255e8f
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Autor:
Lixin Wei, Honghui Tang, Jiaming Zhao, Shiyi Chen, Yiqiang Xie, Shilin Feng, Zhisheng Xu, Zihan Yu
Publikováno v:
Fire, Vol 6, Iss 11, p 444 (2023)
To investigate the fire risk in a complex tunnel with varying cross-sections, sloped structures, and dense upper cover beams, this study considered four fire source positions: the immersed tube section, confluence section, highway auxiliary road sect
Externí odkaz:
https://doaj.org/article/1e5a6cc3f8784eb38cb0eeffdf1cfa27
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Publikováno v:
Buildings, Vol 13, Iss 5, p 1316 (2023)
The frequently conventional assumption that bridge temperature is uniformly distributed on long-span bridges could lead to uncertainty when analyzing temperature effects. This study investigated the surface temperature of steel box girders on a long-
Externí odkaz:
https://doaj.org/article/5e256c66c73142cf9ae4d48ffcb7c2f9
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Publikováno v:
Case Studies in Thermal Engineering, Vol 26, Iss , Pp 101032- (2021)
By sealing the portal at one end of tunnel and changing the transverse location of linear fire source in tunnel, the hot smoke layer, longitudinal temperature distribution and maximum temperature of linear fire source were investigated. It is found t
Externí odkaz:
https://doaj.org/article/0da2378c6e99458eb2b83434fdcc6911