Zobrazeno 1 - 6
of 6
pro vyhledávání: '"induction-dynamic catapult"'
Publikováno v:
Метрологія та прилади, Iss 6, Pp 45-50 (2017)
The limiting deviations of the trajectory of the free flight of the test body from the vertical are estimated, which can lead to disruption of interference in the laser-optical receiving-emitting device of a ballistic laser gravimeter with a symmetri
Externí odkaz:
https://doaj.org/article/6efe0077c0a54eb08dc0e89b78271f39
Publikováno v:
Український метрологічний журнал / Ukrainian Metrological Journal; № 4 (2021); 20-27
Украинский метрологический журнал / Ukrainian Metrological Journal; № 4 (2021); 20-27
Ukrainian Metrological Journal; No. 4 (2021); 20-27
Украинский метрологический журнал / Ukrainian Metrological Journal; № 4 (2021); 20-27
Ukrainian Metrological Journal; No. 4 (2021); 20-27
The purpose of the study is to analyse the influence of the excitation of an induction-dynamic catapult of a ballistic laser gravimeter from an AC voltage source at different frequencies on electromechanical indicators that provide a reduced value of
Publikováno v:
Український метрологічний журнал; № 3 (2020); 3-11
Украинский метрологический журнал; № 3 (2020); 3-11
Ukrainian Metrological Journal; № 3 (2020); 3-11
Украинский метрологический журнал; № 3 (2020); 3-11
Ukrainian Metrological Journal; № 3 (2020); 3-11
In order to reduce auto seismic oscillations in the ballistic laser gravimeters (BLG) with a symmetric method of measuring the gravitational acceleration (GA), an induction-dynamic catapult (IDC) is used, which is excited by a pulse packet from a cap
Publikováno v:
Український метрологічний журнал; № 2 (2016); 15-20
Украинский метрологический журнал; № 2 (2016); 15-20
Ukrainian Metrological Journal; № 2 (2016); 15-20
Украинский метрологический журнал; № 2 (2016); 15-20
Ukrainian Metrological Journal; № 2 (2016); 15-20
The paper considers a ballistic laser gravimeter (BLG) with a symmetrical way of gravity acceleration (GA) measuring, which has measurement errors due to the vertical movement of a test body. The effectiveness of implementing vibration damping method
Autor:
V. F. Bolyukh, A. I. Vinnichenko
A design is proposed for an inductive-dynamic catapult in a ballistic laser gravimeter with a fixed inductor and an electrically conducting armature that moves together with the test object along a vertical axis. The catapult ensures improved accurac
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::f40512c605af42f2e6abc396deda5daa
http://repository.kpi.kharkov.ua/handle/KhPI-Press/14895
http://repository.kpi.kharkov.ua/handle/KhPI-Press/14895
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.