Zobrazeno 1 - 10
of 50
pro vyhledávání: '"hip joint prostheses"'
Autor:
Fang, Xingxing, Li, Dahan, Xin, Yucheng, Wang, Songquan, Guo, Yongbo, Hu, Ningning, Zhang, Dekun
Publikováno v:
Industrial Lubrication and Tribology, 2021, Vol. 73, Issue 10, pp. 1302-1309.
Externí odkaz:
http://www.emeraldinsight.com/doi/10.1108/ILT-07-2021-0261
Publikováno v:
Volume 14: Design, Systems, and Complexity.
Nowadays, healthcare centers are not familiar with quantitative approaches for patients’ gait evaluation. There is a clear need for methods to obtain objective figures characterizing patients’ performance. Actually, there are no diffused methods
Publikováno v:
Materials, Vol 10, Iss 7, p 744 (2017)
Materials; Volume 10; Issue 7; Pages: 744
Materials
Materials; Volume 10; Issue 7; Pages: 744
Materials
Biolox® delta has been widely used in joint replacements thanks to its high strength and wear resistance. In this study, eleven Biolox® delta femoral head retrievals affected by metal transfer (MT) were analysed by Raman spectroscopy to estimate th
Autor:
Mohammad Uddin, Liangchi Zhang
Publikováno v:
Wear. 301:192-200
The wear of the bearing surfaces of hip joint prostheses is a key problem causing their primary failure. This paper introduces a wear prediction model with the aid of the finite element analysis. To mimic walking, the most common activity of a human
Publikováno v:
Wear. 270:584-590
Replaced hip joints are normally expected to last 15–20 years. However, although the procedure is nowadays successfully performed, up to 10% of procedures carried out are revision operations to replace joints, which have failed prematurely, mainly
Publikováno v:
Medicalbiological engineeringcomputing. 54(10)
Wear is the major cause of implant failure, resulting in expensive revision surgeries of total hip arthroplasty. Therefore, understanding of wear mechanism and its progression is crucial to improve the physiological performance of implants. This pape
Autor:
Ehmaida, Mutyaa M.
Total hip joint prostheses made of CoCrMo heads versus ultra high molecular weight polyethylene (UHMWPE) cups have a limited lifetime, mainly due to the wear of the UHMWPE cups as a result of high friction between the articulating surfaces leading to
Externí odkaz:
http://hdl.handle.net/10454/5665
Autor:
Ehmaida, Mutyaa M.
Total hip joint prostheses made of CoCrMo heads versus ultra high molecular weight polyethylene (UHMWPE) cups have a limited lifetime, mainly due to the wear of the UHMWPE cups as a result of high friction between the articulating surfaces leading to
Externí odkaz:
http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.582964
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.