Zobrazeno 1 - 10
of 37
pro vyhledávání: '"heart cycle"'
Autor:
van Eijnatten Maureen A.J.M., van Rijssel Michael J., Peters Rob J.A., Verdaasdonk Rudolf M., Meijer Jan H.
Publikováno v:
Journal of Electrical Bioimpedance, Vol 5, Iss 1, Pp 2-8 (2014)
The non-invasively measured initial systolic time interval (ISTI) reflects a time difference between the electrical and pumping activity of the heart and depends on cardiac preload, afterload, autonomic nervous control and training level. However, th
Externí odkaz:
https://doaj.org/article/25f03c1560e841df9d547879569c5bc5
Publikováno v:
Frontiers in Neurorobotics, Vol 8 (2014)
Internal signals like one's heartbeats are centrally processed via specific pathways and both their neural representations as well as their conscious perception (interoception) provide key information for many cognitive processes. Recent empirical fi
Externí odkaz:
https://doaj.org/article/b24178a5df1b4b3e8467d6a758b8bac4
Autor:
Carl-Johan Carlhäll, Daniel Forsberg, Mariana Bustamante, Jan Engvall, Tino Ebbers, Vikas Gupta
Publikováno v:
Medical Image Analysis. 49:128-140
Four-dimensional (4D) flow magnetic resonance imaging (4D Flow MRI) enables acquisition of time-resolved three-directional velocity data in the entire heart and all major thoracic vessels. The segmentation of these tissues is typically performed usin
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
This paper proposes a novel automatic heart sounds segmentation method for deployment in heart valve defect diagnosis. The method is based on the correlation coefficients matrix, calculated between all the heart cycles for similarity identification.
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::ccd17be9e825a2168cd51431ab990e63
https://doi.org/10.1016/j.bspc.2018.03.009
https://doi.org/10.1016/j.bspc.2018.03.009
Autor:
Vladimir V. Chepenko
Publikováno v:
Cardiometry, Iss 4, Pp 151-155 (2014)
In the paper presented is an application study of the heart performance phase mechanism with the use of the Cardiocode analyzer based on principles of cardiometry for evaluating iatrogenic complications caused by antiarrhythmic therapy and monitoring
Autor:
Jan H. Meijer, Rudolf M. Verdaasdonk, Michael J. van Rijssel, Maureen van Eijnatten, Rob J.A. Peters
Publikováno v:
van Eijnatten, M A J M, van Rijssel, M J, Peters, R J A, Verdaasdonk, R M & Meijer, J H 2014, ' Comparison of cardiac time intervals between echocardiography and impedance cardiography at various heart rates. ', Journal of Electrical Bioimpedance, vol. 5, pp. 2-8 . https://doi.org/10.5617/jeb.690
Journal of Electrical Bioimpedance, 5, 2-8. Oslo Bioimpedance Group, Department of Physics, University of Oslo
Journal of Electrical Bioimpedance, Vol 5, Iss 1, Pp 2-8 (2014)
Journal of Electrical Bioimpedance, 5, 2-8. Oslo Bioimpedance Group, Department of Physics, University of Oslo
Journal of Electrical Bioimpedance, Vol 5, Iss 1, Pp 2-8 (2014)
The non-invasively measured initial systolic time interval (ISTI) reflects a time difference between the electrical and pumping activity of the heart and depends on cardiac preload, afterload, autonomic nervous control and training level. However, th
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Autor:
Konstantine K. Mamberger, Mikhail Y. Rudenko, Dmitry F. Makedonsky, Olga K. Voronova, Sergey M. Rudenko, Vladimir A. Zernov
Publikováno v:
Cardiometry, Iss 1, Pp 132-141 (2012)
Aims Criteria of identification of individual heart cycle phases according to an ECG curve are described in this paper. Materials and methods For this study, a single-lead system ECG is used only. Its distinctive feature is that an ECG signal is reco