Publikováno v:
南方能源建设, Vol 10, Iss 2, Pp 110-118 (2023)
[Introduction] Lightning strike is the primary cause of failures of ±800 kV UHVDC power transmission lines, and the lightning protection assessment of power transmission lines is critical to the safe and stable operation of the system. [Method] Base
Externí odkaz:
https://doaj.org/article/55b12fc38dee4500b8878de0056a131c
Publikováno v:
IEEE Open Access Journal of Power and Energy, Vol 8, Pp 522-531 (2021)
In the usual practice, the evaluation of overvoltages due to direct lightning strikes to overhead power lines is focused on the representation of the effects of the lightning current injection, whilst the effects of the coupling between the conductor
Externí odkaz:
https://doaj.org/article/0f02ed34e7a3465b8ee279f3603ffe2b
Publikováno v:
High Voltage (2019)
Here, using the probabilistic evaluation based on the Monte Carlo method, back-flashover rate and shielding failure flashover rate of 230 kV overhead transmission lines in the western regions of Iran are evaluated. To such an aim, first, the number o
Externí odkaz:
https://doaj.org/article/d399f9a31ab04c9788444272c336b440
Autor:
Edison Soto, Ernesto Pérez
Publikováno v:
TecnoLógicas, Vol 21, Iss 42, Pp 51-62 (2018)
This paper presents the implementation of an analytical formulation to calculate the lightning electromagnetic pulse (LEMP) assuming a current wave-shape linearly rising with flat top and a transmission Line (TL) return-stroke model. It also describe
Externí odkaz:
https://doaj.org/article/4f1e982ec56f468fae734991f96e1b59
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Publikováno v:
SAIEE Africa Research Journal, Volume: 113, Issue: 3, Pages: 108-118, Published: SEP 2022
Lightning strikes near Medium Voltage (MV) electricity distribution lines cause voltage transients to be induced onto the conductors of the power lines. The resultant Lightning Induced Overvoltage (LIOV) on the phase conductors may be estimated using
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::8f678f6fba40e78771c2de8c0ed50f64
http://www.scielo.org.za/scielo.php?script=sci_arttext&pid=S1991-16962022000300001&lng=en&tlng=en
http://www.scielo.org.za/scielo.php?script=sci_arttext&pid=S1991-16962022000300001&lng=en&tlng=en
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Publikováno v:
ITB Journal of Engineering Science, Vol 41, Iss 2, Pp 126-140 (2009)
Two feeders of 20 kV overhead distribution lines which are located in a high lightning density area are chosen to be observed as a field study due to their good lightning performance after improvement of lightning protection system. These two feeders
Externí odkaz:
https://doaj.org/article/024643e749ee42558d1d7f1a090da8a4
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
In medium-voltage distribution lines, lightning outages associated with indirect strokes are less frequent when surge arresters are installed at close intervals. In this case, the lightning performance is mainly determined by the line response due to
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::78992e00c47e8aa8b53ba75a61d508c6
http://hdl.handle.net/11585/857220
http://hdl.handle.net/11585/857220