Zobrazeno 1 - 10
of 27
pro vyhledávání: '"Zushi Tian"'
Publikováno v:
npj Materials Degradation, Vol 8, Iss 1, Pp 1-11 (2024)
Abstract Considering the complex coupling of steel corrosion in partially saturated concrete filled with water, the quantitative description of control mechanisms is still under debate. This work provides new experimental evidence supporting that dif
Externí odkaz:
https://doaj.org/article/30855ff106104f348c44c204f566cf0e
Publikováno v:
Case Studies in Construction Materials, Vol 18, Iss , Pp e02021- (2023)
Crack location and type identification of reinforced concrete columns in service is of great interest to researchers, since it influences the decision-making of maintenance and retrofit. Due to the existing of load and corrosion, the complex stress s
Externí odkaz:
https://doaj.org/article/d79a0115a861454bb86c7a60631c0272
Autor:
Ye Tian, Guoyi Zhang, Hailong Ye, Qiang Zeng, Zhidong Zhang, Zushi Tian, Xianyu Jin, Nanguo Jin, Zhonggou Chen, Jiaxi Wang
Publikováno v:
Construction and Building Materials. 369:130504
Publikováno v:
Cement and Concrete Composites. 134:104743
Autor:
Zushi Tian, Hailong Ye
Publikováno v:
Cement and Concrete Research. 159:106867
Publikováno v:
Construction and Building Materials. 221:443-455
In order to demonstrate the three-dimensional chloride ions diffusion in real concrete, the X-ray CT technique was applied to reconstruct the meso- and micro-structure of concrete. An improved threshold method was used to eliminate the noise during X
Publikováno v:
Materials and Structures. 53
The internal structure of composite materials is usually composed of a continuous matrix with dispersed particles. To simulate the spatial distribution of particles, the random sequential addition algorithm (RSA) is commonly used. The RSA using conti
Publikováno v:
Construction and Building Materials. 178:432-444
In order to demonstrate the chlorides ions diffusion in concrete, a multi-phase numerical model was established at mesoscale. The thickness of interfacial transition zone (ITZ) surrounding aggregate was measured based on an element analysis using ele
Publikováno v:
Construction and Building Materials. 299:123946
Ultra-high performance concrete (UHPC) shows volumetric instability at high temperatures because of explosive spalling. Polypropylene (PP) fibers are effective in mitigating the explosive spalling of UHPC; however, the threshold PP fiber dosage to pr
Autor:
Hailong Ye, Zushi Tian
Publikováno v:
Cement and Concrete Composites. 120:104053
Electrical resistivity is a key durability indicator for evaluating the mass transport properties of cementitious materials particularly in partially-saturated states. In this work, the electrical resistivity of alkali-activated slag (AAS) with and w