Zobrazeno 1 - 7
of 7
pro vyhledávání: '"Zuchang Li"'
Autor:
Yong Yang, Bin Li, Zuchang Li, Qipei Wei, Huachao Shan, Yuan Li, Fangfang Duan, Xiaohui Niu, Guanglei Tian
Publikováno v:
Plastic & Reconstructive Surgery; Aug2024, Vol. 154 Issue 2, p374e-377e, 4p
Publikováno v:
Medical Engineering & Physics. 93:8-16
Osteoporosis is characterized by reduced bone strength predisposing to an increased risk of fracture. Biomechanical computed tomography (BCT), predicting bone strength via CT-based finite element analysis (FEA), is now clinically available in the USA
Publikováno v:
Orthopaedic Surgery
Orthopaedic Surgery, Vol 13, Iss 1, Pp 202-206 (2021)
Orthopaedic Surgery, Vol 13, Iss 1, Pp 202-206 (2021)
Objective Lumbar spondylolisthesis (LS) is a common lumbar disease, and the prevalence of LS in different countries or regions was not consistent in the past. This study intends to make statistics on the prevalence of lumbar spondylolisthesis in midd
Autor:
Wentian Feng, Yi Wei, Fei Song, Zuchang Li, Ruisen Fu, Rahman Ud Din, Jieren Li, Wancheng Liu, Yuxuan Liu, Haisheng Yang
Publikováno v:
Medical engineeringphysics. 108
Biomechanical CT (BCT), i.e., quantitative computed tomography-based finite element analysis (QCT-FEA), promises an improved technique over bone mineral density (BMD) in predicting bone strength and the risk of osteoporotic vertebral fractures. Howev
Autor:
Fei, Song, Yi, Wei, Wentian, Feng, Ruisen, Fu, Zuchang, Li, Xing, Gao, Xiaoguang, Cheng, Haisheng, Yang
Publikováno v:
Bone. 166:116601
Following primary fractures and percutaneous kyphoplasty (PKP), patients have a high risk of incurring a subsequent vertebral fracture (SVF). Given that SVF is a consequence of mechanical deterioration of the vertebra, we sought to examine whether ve
Autor:
Jingwei Zhao, Wei Tian, Sai Ma, Mingxing Fan, Zhan Shi, Qilong Wang, Zuchang Li, Da He, Bo Liu, Yajun Liu, Lang Zhao
Objective To explore navigation-related factors interfering with accuracy of robot-assisted surgery. Methods We made a measurement model to test the accuracy of the TianJi Robot system when performing the stimulated screw placement procedure. The thr
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::ee1e36f8ea33aa49630ad81775c23a46
https://doi.org/10.21203/rs.3.rs-832508/v1
https://doi.org/10.21203/rs.3.rs-832508/v1
Autor:
Qingpeng, Song, Wei, Tian, Da, He, Xiao, Han, Ning, Zhang, Jinchao, Wang, Zuchang, Li, Xiao, Feng
Publikováno v:
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi
OBJECTIVE: To evaluate the influence of the shell angle of cervical artificial disc on long-term effectiveness of cervical artificial disc replacement (CADR). METHODS: The clinical data of 71 patients who were treated with single-level CADR with Brya