Zobrazeno 1 - 10
of 21
pro vyhledávání: '"Zoltán Gingl"'
Publikováno v:
Scientific Reports, Vol 14, Iss 1, Pp 1-17 (2024)
Abstract The scale-free nature of daily human activity has been observed in different aspects; however, the description of its spectral characteristics is incomplete. General findings are complicated by the fact that—although actigraphy is commonly
Externí odkaz:
https://doaj.org/article/8448f46b9dcd469cb21384840817a243
Autor:
Szabolcs Baglyas, Luca Valkó, Vivien Móró, Eszter Podmaniczky, Dorottya Czövek, Gergely Makan, Zoltán Gingl, János Gál, Zoltán Hantos, András Lorx
Publikováno v:
BMC Pulmonary Medicine, Vol 23, Iss 1, Pp 1-12 (2023)
Abstract Background Continuous positive airway pressure (CPAP) therapy has profound effects in obesity hypoventilation syndrome (OHS). Current therapy initiation focuses on upper airway patency rather than the assessment of altered respiratory mechan
Externí odkaz:
https://doaj.org/article/5688ecfa36d34476853046f1a122e00f
Autor:
Bence L. Radics, Zita Gyurkovits, Gergely Makan, Zoltán Gingl, Dorottya Czövek, Zoltán Hantos
Publikováno v:
Frontiers in Pediatrics, Vol 10 (2022)
BackgroundOscillometry has been employed widely as a non-invasive and standardized measurement of respiratory function in children and adults; however, limited information is available on infants.AimsTo establish the within-session variability of res
Externí odkaz:
https://doaj.org/article/f2ab5b1892ca4deb84e3305bc355cfd4
Autor:
Ádám Nagy, József Dombi, Martin Patrik Fülep, Emese Rudics, Emőke Adrienn Hompoth, Zoltán Szabó, András Dér, András Búzás, Zsolt János Viharos, Anh Tuan Hoang, Bálint Maczák, Gergely Vadai, Zoltán Gingl, Szandra László, Vilmos Bilicki, István Szendi
Publikováno v:
Sensors, Vol 23, Iss 2, p 958 (2023)
(1) Background and Goal: Several studies have investigated the association of sleep, diurnal patterns, and circadian rhythms with the presence and with the risk states of mental illnesses such as schizophrenia and bipolar disorder. The goal of our st
Externí odkaz:
https://doaj.org/article/35b0550f25da45daada3e0ee5206f314
Publikováno v:
PLoS ONE, Vol 16, Iss 12, p e0261718 (2021)
Actigraphic measurements are an important part of research in different disciplines, yet the procedure of determining activity values is unexpectedly not standardized in the literature. Although the measured raw acceleration signal can be diversely p
Externí odkaz:
https://doaj.org/article/dd5fb93743ea4718b7ac20cc7e3fea59
Publikováno v:
Royal Society Open Science, Vol 3, Iss 2 (2016)
Recently, we have reported on a compact microcontroller-based unit developed to accurately synchronize excimer laser pulses (Mingesz et al. 2012 Fluct. Noise Lett. 11, 1240007 (doi:10.1142/S021947751240007X)). We have shown that dithering based on ra
Externí odkaz:
https://doaj.org/article/3be020377287426eaadc4969d4cf20b5
Although actigraphy is commonly used in many research areas, the activity calculation methods are not standardized, therefore activity signals can be very different. The scale-free nature of daily human activity has been observed in different aspects
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::fb6386b9df84d2e2a9184dff062a6577
https://doi.org/10.21203/rs.3.rs-2539448/v1
https://doi.org/10.21203/rs.3.rs-2539448/v1
Autor:
Szabolcs Baglyas, Luca Valkó, Vivien Móró, Eszter Podmaniczky, Dorottya Czövek, Gergely Makan, Zoltán Gingl, János Gál, Zoltán Hantos, András Lorx
Background Altered respiratory mechanics due to increased extrapulmonary mechanical load may be the key to understanding the profound effect of continuous positive airway pressure (CPAP) therapy in obesity hypoventilation syndrome (OHS). Methods We p
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::e415c1b0f10e750c418e550919cf5263
https://doi.org/10.21203/rs.3.rs-1726064/v1
https://doi.org/10.21203/rs.3.rs-1726064/v1
Publikováno v:
IEEE Access, Vol 12, Pp 38102-38111 (2024)
This paper presents a simple, lightweight, automatic calibration method for low-cost triaxial accelerometers, utilizing the Earth’s gravitational constant in various orientations. It can be easily implemented using only fixed-point arithmetic and c
Externí odkaz:
https://doaj.org/article/b58b792bb0fb48c798f822d85c82f3dc
Autor:
Zoltán, Hantos, Dorottya, Czövek, Zita, Gyurkovits, Hajnalka, Szabó, Balázs A, Maár, Bence, Radics, Katalin, Virág, Gergely, Makan, Hajnalka, Orvos, Zoltán, Gingl, Peter D, Sly
Publikováno v:
Pediatric pulmonology. 50(4)
Lung function data in healthy newborn infants are scarce largely due to lack of suitable techniques, although data for developmental and prenatal exposure studies are much needed. We have modified the forced oscillation technique (FOT) for the measur