Zobrazeno 1 - 10
of 21
pro vyhledávání: '"Ziqiang Chi"'
Autor:
Lisha Guo, Han Wang, Chenru Hao, Ziqiang Chi, Li Cheng, Haibo Yang, Jing Zhang, Ruibin Zhao, Yanru Wu
Publikováno v:
PLoS ONE, Vol 19, Iss 2, p e0297756 (2024)
This paper employs low-field nuclear magnetic resonance (LF-NMR) technology to meticulously analyze and explore the intricate soybean infiltration process. The methodology involves immersing soybeans in distilled water, with periodic implementation o
Externí odkaz:
https://doaj.org/article/125a582c194e4c979a574a26429cf750
Publikováno v:
IEEE Access, Vol 8, Pp 8520-8532 (2020)
Cell microinjection is a direct and effective way to transfer external materials into the cell. In the field of modern biomedicine, cell microinjection is very important, no matter in genetics, reproductive health, tumor therapy or others related res
Externí odkaz:
https://doaj.org/article/c0d0389924f049d0b648379278e476f1
Autor:
Ziqiang Chi, Qingsong Xu
Publikováno v:
International Journal of Advanced Robotic Systems, Vol 11 (2014)
The micro/nano positioning field has made great progress towards enabling the advance of micro/nano technology. Micro/nano positioning stages actuated by piezoelectric actuators are the key devices in micro/nano manipulation. The control of piezoelec
Externí odkaz:
https://doaj.org/article/0db0535412b14c7dbb766ecaee64689c
Design and Testing of a New Microinjector With Capacitive Force Sensor for Biological Microinjection
Publikováno v:
IEEE Transactions on Automation Science and Engineering. :1-11
Publikováno v:
IEEE Transactions on Automation Science and Engineering. 19:3409-3418
Publikováno v:
IEEE Robotics and Automation Letters. 7:1848-1855
Autor:
Li, Cheng, Chenru, Hao, Yanpeng, Wang, Jingjing, Zhang, Yunlong, Wen, Ziqiang, Chi, Xiuyuan, Li, Haibo, Yang, Yanru, Wu, Lisha, Guo, Ruibin, Zhao
Publikováno v:
Technology and Health Care. 30:105-114
BACKGROUND: The results of urine tests are often affected by improper midstream urine collection time, urine spilling, and urine pollution, all of which can lead to an increase in the test error. OBJECTIVE: To solve this problem, aiming at improving
Publikováno v:
IEEE/ASME Transactions on Mechatronics. :1-11
Publikováno v:
IEEE Transactions on Magnetics. 58:1-8
This paper presents the design, optimization, and testing of a new rotating electromagnetic field generation system for actuating magnetic microrobots. Its unique feature lies in that the proposed six-coil electromagnetic actuation system produces a
Publikováno v:
IEEE Access, Vol 8, Pp 8520-8532 (2020)
Cell microinjection is a direct and effective way to transfer external materials into the cell. In the field of modern biomedicine, cell microinjection is very important, no matter in genetics, reproductive health, tumor therapy or others related res