Zobrazeno 1 - 10
of 53
pro vyhledávání: '"Zhu, Deheng"'
Autor:
Zhu, Deheng1 (AUTHOR) zhudeheng2013@yahoo.co.jp, Seki, Hiroaki2 (AUTHOR), Tsuji, Tokuo2 (AUTHOR), Hiramitsu, Tatsuhiro2 (AUTHOR)
Publikováno v:
Sensors (14248220). Sep2022, Vol. 22 Issue 18, p7006-N.PAG. 17p.
Autor:
Lin, Du, Jiang, Lei, Li, Fuqi, Zhu, Deheng **, Tan, Kexiong, Wu, Chengqi, Jin, Xianhe, Wang, Changchang, Cheng, T.C.
Publikováno v:
In Tsinghua Science & Technology 2005 10(5):598-604
Publikováno v:
International Journal of Mechatronics and Automation; 2022, Vol. 9 Issue: 2 p90-98, 9p
Autor:
Li Fuqi, Tan Kexiong, Jin Xianhe, Wu Chengqi, Wang Changchang, Zhu Deheng, Lin Du, T.C. Cheng, Jiang Lei
Publikováno v:
Tsinghua Science and Technology. 10:598-604
This paper introduces a computerized on-line partial discharge (PD) monitoring and diagnostic system for transformers. The system, which is already in use in a power station, uses wide-band active transducers and a data acquisition unit with modulari
Publikováno v:
IEEE Transactions on Dielectrics and Electrical Insulation. 2:700-707
The insulation system of HV apparatus deteriorates due to partial discharges (PD). PD tests are carried out successfully in shielded laboratories to verify the insulation quality and to rectify defects left during the manufacturing process. A variety
Publikováno v:
2002 IEEE Region 10 Conference on Computers, Communications, Control and Power Engineering. TENCOM '02. Proceedings..
An on-line diagnostic expert system (ES) for generators is presented in this paper, in which the automatic diagnostic mode and man-machine interactive diagnostic mode are used to evaluate the state of generators based on the knowledge-based system (K
Publikováno v:
[1991] Proceedings of the 3rd International Conference on Properties and Applications of Dielectric Materials.
A computer-aided online detection system of partial discharges (PDs) in power transformers is described. The impulse electrical signals of PD are detected with a current transducing unit and the acoustic emission signals of the PD are detected with a
Publikováno v:
POWERCON '98. 1998 International Conference on Power System Technology. Proceedings (Cat. No.98EX151).
An artificial neural network (ANN) representation method is presented and discussed in this paper. ANN representation of symbolic and numeric knowledge is realized by the improved backpropagation (BP) algorithm. The method of management and organizat
Publikováno v:
Proceedings of 5th International Conference on Properties and Applications of Dielectric Materials.
The application of Wavelet Transform to extract partial discharge signals from narrow-band disturbance such as sinusoidal interference is described in this paper. Mallat's algorithm of dyadic wavelet transform was used to filter out PD signals. Two k
Publikováno v:
Proceedings of the 6th International Conference on Properties and Applications of Dielectric Materials (Cat. No.00CH36347).
An on-line power equipment monitoring and diagnosis system (PEMDS), which is developed for monitoring multiple parameters of power apparatus, is introduced in this paper. The structure of the system and the principles of development are discussed. PE