Publikováno v:
Clinical Chemistry. 35:545-551
We present an algorithm for monitoring the concentration of human choriogonadotropin (hCG) in serum at various clinical decision levels with use of fast, simple, and cost-effective qualitative pregnancy test reagents for hCG in serum. Based on correl
Publikováno v:
Clinical Chemistry. 27:27-34
We followed the "abbreviated precision protocol" of the National Committee for Clinical Laboratory Standards for the evaluation of precision, accuracy, and carryover in analyses for glucose with the "Ektachem." We analyzed 760 clinical samples by thi
Autor:
Z L Bandi
Publikováno v:
Clinical Chemistry. 27:1676-1681
We find that 2 to 6 mmol of carbon dioxide per liter (mean: 4.1 mmol/L) is lost during routine laboratory processing of patients' serum samples after centrifugation. Additional CO2 may be lost if evacuated blood-collection tubes are not filled comple
Autor:
Ghulam Ansari, Z. L. Bandi
Publikováno v:
Journal of Chromatography A. 363:402-406
Formation, purification et analyse de derives t-butyldimethylsiloxy desters p-nitrobenzyliques d'acides gras monohydroxyles
Publikováno v:
Clinical Chemistry. 31:1601-1605
We estimated analytical errors of the Calbiochem, Kallestad, Hyland, Meloy, Helena, and Beckman immunochemical methods for serum transferrin. Intermethod biases were determined by analysis of the "Reference Preparation for Serum Proteins" of the Coll
Autor:
Ghulam Ansari, Z. L. Bandi
Publikováno v:
Journal of Chromatography A. 435:513-517
Publikováno v:
American Journal of Clinical Pathology. 87:236-242
The performance of six recently introduced highly sensitive enzyme-linked immunosorbent (ELISA) urine pregnancy test reagent kits was evaluated for false positive results using 100 male and 100 postmenopausal female urine specimens and the findings w
Publikováno v:
Clinical Chemistry. 33:677-681
We screened six highly sensitive kits, designed for serum pregnancy tests, for false-positive results. The two best were then evaluated more extensively. The "BETA-hCG MAIA-clone" (I) and the "TANDEM ICON" (II) kits gave only negative results for 100
Publikováno v:
Clinical Chemistry. 27:480-485
We followed the "abbreviated precision protocol" of the National Committee for Clinical Laboratory Standards for the evaluation of precision, accuracy, and carryover in analysis for urea nitrogen with the multilayer film analysis system ("Ektachem").
Publikováno v:
Journal of Chromatography A. 249:93-101
Potential use of quaternary triethylammonium (QAE) Glycophase on controlled pore glass (CPG) for preparative ion-exchange chromatography of liver, brain and soybean lipids was investigated. We found that QAE-Glycophase—CPG bound and held polar and