Zobrazeno 1 - 10
of 18
pro vyhledávání: '"Yukio Agarie"'
Autor:
Mohd Syahmi Jamaludin, Akihiko Hanafusa, Yamamoto Shinichirou, Yukio Agarie, Hiroshi Otsuka, Kengo Ohnishi
Publikováno v:
Bioengineering, Vol 6, Iss 4, p 98 (2019)
In this study, we estimated and validated the pressure distribution profile between the residuum and two types of prosthetic sockets for transfemoral amputees by utilizing a finite element analysis. Correct shaping of the socket for an appropriate lo
Externí odkaz:
https://doaj.org/article/92d2f61d2c1140e59a592e666173e2e8
Autor:
Mohd Syahmi Jamaludin, Akihiko Hanafusa, Yamamoto Shinichirou, Yukio Agarie, Hiroshi Otsuka, Kengo Ohnishi
Publikováno v:
Applied Sciences, Vol 9, Iss 18, p 3662 (2019)
Recent technologies have suggested the utilization of three-dimensional (3D) printing technology to enhance the fabrication accuracy of prosthetics. Accordingly, simulations are used to obtain precise parameters for subject-specified prosthetic socke
Externí odkaz:
https://doaj.org/article/116de4d946d34a13aef40fa1dcdd31dd
Autor:
Yukio Agarie, Motohiko Takahashi, Toshio Soma, Takahiro Go, Yu Maeda, Hironori Suda, Toyohiko Hayashi
Publikováno v:
Journal of the Society of Biomechanisms. 44:242-251
Publikováno v:
Journal of physical therapy science. 34(4)
[Purpose] This study aimed to objectively clarify the effect of the trim line setting on the stiffness of posterior leaf spring ankle-foot orthoses. [Participant and Methods] Posterior leaf spring ankle-foot orthoses were fabricated with two thicknes
Autor:
Hiroshi Otsuka, Ryogo Suzuki, Shin ichiro Yamamoto, Yukio Agarie, Akihiko Hanafusa, Kengo Ohnishi, Mohd Syahmi Jamaludin, Hayato Ikebata, Taiki Kawamura, Le Van Tuan
Publikováno v:
IFMBE Proceedings ISBN: 9783030661687
The fit of prostheses and orthoses is important, because, if the fit is inadequate, patients may feel uncomfortable. A poor fit can cause difficulty in gait, and, in the worst cases, it can cause inflammation. An evaluation system for checking the fi
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::b0db0466523a4272e056862f032ff86f
https://doi.org/10.1007/978-3-030-66169-4_13
https://doi.org/10.1007/978-3-030-66169-4_13
Autor:
Yukio Agarie, Shin-ichiroh Yamamoto, Hiroshi Otsuka, Tran Van Thuc, Kengo Ohnishi, Akihiko Hanafusa
Publikováno v:
IFMBE Proceedings ISBN: 9783030661687
Recently, the development of the technological advances of the prosthesis socket has been considered. However, the successful fitting of the prosthesis socket to the residuum stump is still not satisfied and existing limitations. The investigation of
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::5a9b058366a7c7006ed935cfb3052911
https://doi.org/10.1007/978-3-030-66169-4_14
https://doi.org/10.1007/978-3-030-66169-4_14
Autor:
Yukio Agarie, Akihiko Hanafusa, Kengo Ohnishi, Shinichiro Yamamoto, Le Van Tuan, Hiroshi Otsuka
Publikováno v:
Journal of Biomimetics, Biomaterials and Biomedical Engineering. 33:1-11
Ground reaction forces (GRF) and pressure beneath the foot prosthesis are the main parameters used in biomechanical analysis to estimate the joint load and evaluate the quality of the prosthesis, especially with transfemoral patient who have amputati
Publikováno v:
Journal of the Society of Biomechanisms. 41:27-34
Autor:
Hiroshi Otsuka, Yamamoto Shinichirou, Yukio Agarie, Mohd Syahmi Jamaludin, Kengo Ohnishi, Akihiko Hanafusa
Publikováno v:
Bioengineering, Vol 6, Iss 4, p 98 (2019)
Bioengineering
Volume 6
Issue 4
Bioengineering
Volume 6
Issue 4
In this study, we estimated and validated the pressure distribution profile between the residuum and two types of prosthetic sockets for transfemoral amputees by utilizing a finite element analysis. Correct shaping of the socket for an appropriate lo
Autor:
Yamamoto Shinichirou, Yukio Agarie, Mohd Syahmi Jamaludin, Hiroshi Otsuka, Kengo Ohnishi, Akihiko Hanafusa
Publikováno v:
Applied Sciences, Vol 9, Iss 18, p 3662 (2019)
Applied Sciences
Volume 9
Issue 18
Applied Sciences
Volume 9
Issue 18
Recent technologies have suggested the utilization of three-dimensional (3D) printing technology to enhance the fabrication accuracy of prosthetics. Accordingly, simulations are used to obtain precise parameters for subject-specified prosthetic socke