Zobrazeno 1 - 10
of 60
pro vyhledávání: '"Yue-Houng Hu"'
Autor:
Yue-Houng Hu, PhD, Riley H. Harper, Noelle C. Deiter, CMD, RTT, Jaden D. Evans, MD, Anita Mahajan, MD, Jon J. Kruse, PhD, Daniel W. Mundy, PhD
Publikováno v:
International Journal of Particle Therapy, Pp 49-58 (2022)
Purpose: Finite proton range affords improved dose conformality of radiation therapy when patient regions-of-interest geometries are well characterized. Substantial changes in patient anatomy necessitate re-planning (RP) to maintain effective, safe t
Externí odkaz:
https://doaj.org/article/df45ad04659f4f889d312eaaa829aac2
Autor:
Shu-Hui Hsu, Zhaohui Han, Jonathan E. Leeman, Yue-Houng Hu, Raymond H. Mak, Atchar Sudhyadhom
Publikováno v:
Frontiers in Oncology, Vol 12 (2022)
Current MRI-guided adaptive radiotherapy (MRgART) workflows require fraction-specific electron and/or mass density maps, which are created by deformable image registration (DIR) between the simulation CT images and daily MR images. Manual density ove
Externí odkaz:
https://doaj.org/article/98f317057c454e7e9c419e0e718d45d4
Autor:
Yue‐Houng Hu, Wan Chan Tseung Hok Seum, Ashley Hunzeker, Olivia Muller, Robert L. Foote, Daniel W. Mundy
Publikováno v:
Journal of Applied Clinical Medical Physics.
Autor:
Zhaohui Han, Atchar Sudhyadhom, Shu‐Hui Hsu, Yue‐Houng Hu, Raymond H. Mak, Mai Anh Huynh, Ritchell R. van Dams, Shyam Tanguturi, Veena Venkatachalam, Joseph D. Mancias, Harvey J. Mamon, Neil E. Martin, Miranda B. Lam, Jonathan E. Leeman
Publikováno v:
Journal of Applied Clinical Medical Physics.
Publikováno v:
Medical Physics. 49:2904-2913
Dental fixtures are commonplace in an aging, radiation treatment population. The current, local standard of practice in particle therapy is to employ treatment geometries to avoid delivery through implanted dental fixtures. The present study aims to
Autor:
Yue‐Houng Hu, Susannah V. Hickling, Jing Qian, C. Robert Blackwell, Luke B. McLemore, Erik J. Tryggestad
Publikováno v:
Journal of Applied Clinical Medical Physics. 23
The Leksell Gamma Knife Icon unit (IU) was introduced recently as an upgrade to the Perfexion unit (PU) at our Gamma Knife practice. In the current study, we sought mainly to characterize dosimetry and targeting accuracy of the IU treatment deliverie
Autor:
Yue-Houng Hu, Riley H. Harper, Noelle C. Deiter, Jaden D. Evans, Anita Mahajan, Jon J. Kruse, Daniel W. Mundy
Publikováno v:
International journal of particle therapy. 9(2)
Purpose Finite proton range affords improved dose conformality of radiation therapy when patient regions-of-interest geometries are well characterized. Substantial changes in patient anatomy necessitate re-planning (RP) to maintain effective, safe tr
Autor:
Dianne Ferguson, Thomas C. Harris, Adam Wang, Christopher S. Williams, Ingrid Valencia-Lozano, Ross Berbeco, M. Jacobson, Daniel Morf, Mengying Shi, Yue-Houng Hu, Rony Fueglistaller, Pascal Huber, Mathias Lehmann, Marios Myronakis, Paul Baturin
Publikováno v:
Physics in medicine and biology. 66(13)
Simultaneous acquisition of cone beam CT (CBCT) projections using both the kV and MV imagers of an image guided radiotherapy system reduces set-up scan times-a benefit to lung cancer radiation oncology patients-but increases noise in the 3D reconstru
Autor:
Daniel Morf, Adam Wang, Marios Myronakis, Paul Baturin, Joerg Rottmann, Ross Berbeco, Daniel Shedlock, Josh Star-Lack, Yue-Houng Hu
Publikováno v:
Medical Physics. 44:4213-4222
Purpose A novel Megavoltage (MV) multi-layer imager (MLI) design featuring higher detective quantum efficiency and lower noise than current conventional MV imagers in clinical use has been recently reported. Optimization of the MLI design for multipl
Autor:
Thomas C. Harris, Marios Myronakis, Mengying Shi, Mathias Lehmann, Pascal Huber, Yue-Houng Hu, Rony Fueglistaller, Paul Baturin, Daniel Morf, M. Jacobson, Ross Berbeco, Adam Wang, Dianne Ferguson
Publikováno v:
Physics in medicine and biology. 64(9)
We have developed a novel method for fast image simulation of flat panel detectors, based on the photon energy deposition efficiency and the optical spread function (OSF). The proposed method, FastEPID, determines the photon detection using photon en