Zobrazeno 1 - 10
of 161
pro vyhledávání: '"Yuan‐Yih Hsu"'
Autor:
Kuei-Yen Lee, Yuan-Yih Hsu
Publikováno v:
Energies, Vol 17, Iss 13, p 3208 (2024)
Ancillary frequency controllers such as droop controllers are beneficial for frequency regulation of a microgrid with high penetration of wind generators. However, the use of such ancillary frequency controllers may cause torsional oscillation in the
Externí odkaz:
https://doaj.org/article/c773a2aa983d478fa11291be04617082
Publikováno v:
IET Renewable Power Generation, Vol 17, Iss 9, Pp 2315-2334 (2023)
Abstract Load changes in a microgrid comprising diesel generators and wind turbines cause oscillations in system frequency. In this paper, an analytical model that takes wind generator speed deviation into account is proposed to evaluate the oscillat
Externí odkaz:
https://doaj.org/article/1a7f6a2d34fb4e199eb0157968378bfc
Publikováno v:
IET Renewable Power Generation, Vol 16, Iss 8, Pp 1685-1698 (2022)
Abstract This paper proposes a generalized piecewise linear time‐variable droop frequency controller with a ramp‐up period for a de‐loaded wind turbine generator. The authors present an analytical model using a simplified system frequency respo
Externí odkaz:
https://doaj.org/article/2b92678d127b4466839ebec415718de8
Publikováno v:
Energies, Vol 16, Iss 21, p 7439 (2023)
Ancillary frequency control schemes (e.g., droop control) are used in wind farms to improve frequency regulation in grids with substantial renewable energy penetration; however, droop controllers can have negative impacts on the damping of wind turbi
Externí odkaz:
https://doaj.org/article/56f3962175e848a4995d2fccd17c0ec1
Publikováno v:
Energies, Vol 14, Iss 20, p 6670 (2021)
A de-loaded real power control strategy is proposed to decrease the real power output and increase the reactive power output of a grid-connected offshore wind farm in order to improve the voltage profile when the wind farm is subject to a grid fault.
Externí odkaz:
https://doaj.org/article/f5dfc5ce57dd449a8db086452ac5ec77
Autor:
Yi-Wei Chen, Yuan-Yih Hsu
Publikováno v:
Energies, Vol 13, Iss 22, p 6135 (2020)
To improve frequency nadir following a disturbance and avoid under-frequency load shedding, two types of flexible kinetic energy release controllers for the doubly fed induction generator (DFIG) are proposed. The basic idea is to release only a small
Externí odkaz:
https://doaj.org/article/77ed705f7f9d4ea2b92cd6a8c77d7635
Publikováno v:
Energies, Vol 13, Iss 20, p 5320 (2020)
An artificial neural network (ANN)-based supplementary frequency controller is designed for a doubly fed induction generator (DFIG) wind farm in a local power system. Since the optimal controller gain that gives highest the frequency nadir or lowest
Externí odkaz:
https://doaj.org/article/45c1523cfee74e51b7d1285d3e7776a2
Publikováno v:
IET Renewable Power Generation. 17:1654-1669
Publikováno v:
Energies, Vol 14, Iss 6670, p 6670 (2021)
Energies; Volume 14; Issue 20; Pages: 6670
Energies; Volume 14; Issue 20; Pages: 6670
A de-loaded real power control strategy is proposed to decrease the real power output and increase the reactive power output of a grid-connected offshore wind farm in order to improve the voltage profile when the wind farm is subject to a grid fault.
Publikováno v:
IET Generation, Transmission & Distribution. 13:563-574
Linearised model for frequency control of an islanding system comprising an equivalent synchronous generator and an equivalent doubly fed induction generator (DFIG) is derived. Small signal stability analysis is performed to determine the stable regi