Zobrazeno 1 - 8
of 8
pro vyhledávání: '"Yu. V. Mokrov"'
Autor:
Yu. V. Mokrov, S. V. Morozova, G. N. Timoshenko, V. A. Krylov, O. B. Badunov, G. A. Seilkhanova
Publikováno v:
Eurasian Journal of Physics and Functional Materials, Vol 2, Iss 4, Pp 307-314 (2021)
The paper presents the results of correction of readings of DVBN-01 albedo dosimeters behind IBR-2M protection, the Neutron Physics Laboratory of the Joint Institute for Nuclear Research (JINR), Dubna, byvarious methods. The neutron spectra were meas
Externí odkaz:
https://doaj.org/article/d7cce2b647194d4596af84575b0deefd
Autor:
G. N. Timoshenko, Yu. V. Mokrov, O.B. Badunov, S. V. Morozova, V. A. Krylov, G.A. Seilkhanova
Publikováno v:
Eurasian Journal of Physics and Functional Materials, Vol 2, Iss 4, Pp 307-314 (2018)
The paper presents the results of correction of readings of DVBN-01 albedo dosimeters behind IBR-2M protection, the Neutron Physics Laboratory of the Joint Institute for Nuclear Research (JINR), Dubna, by various methods. The neutron spectra were mea
Publikováno v:
Physics of Particles and Nuclei Letters. 11:809-817
The results of correcting the readings of DVGN-01 albedo dosimeters behind the shielding of the MC400 cyclotron at the Laboratory of Nuclear Reactions (LNR) with the use of the spherical albedo system are presented. The formulas approximating the dep
Autor:
Yu. V. Mokrov, S. V. Morozova
Publikováno v:
Physics of Particles and Nuclei Letters. 11:127-136
Results of calibrating a spherical albedo system in the radiation fields of a Pu-Be radionuclide neutron source are presented. It is shown that it can be used for correcting the readings of the DVGN-01 albedo dosimeter. The results of measurements wi
Publikováno v:
Physics of Particles and Nuclei Letters. 9:192-201
The results of an experimental determination of the sensitivity of three types of individual neutron albedo dosimeters in neutron reference fields on the basis of radionuclide sources and at the top concrete shielding of the U-70 accelerator are pres
Publikováno v:
Physics of Particles and Nuclei Letters. 7:212-221
The calculated results of research into the accuracy of an individual albedo dosimeter DVGN-01 as it corresponds to the personal equivalent dose for neutrons Hp(10) and to the effective dose for neutrons Eeff in the neutron fields at Joint Institute
Publikováno v:
Physics of Particles and Nuclei Letters. 6:78-83
The results of an investigation into the possibility of applying a device based on a 10B neutron counter (CHM-14) with a polyethylene moderator as the dosimeter of neutron ambient dose equivalent H*(10) in radiation fields of nuclear physics installa
Publikováno v:
Soviet Atomic Energy. 42:61-62